Whirlpool ACU124PK0 230/208-voltmodels with amperes up through, Electrical Requirements Continued

Models: ACU124PK0

1 16
Download 16 pages 61.98 Kb
Page 6
Image 6
230/208-volt models with amperes up through 12.0

Electrical Requirements

Continued

Manual backgroundWARNING

Electrical Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Power

3-prong

supply

ground-

cord

type outlet

Ground prong

3-prong ground plug

230/208-volt models with amperes up through 12.0

Outlet wiring

Outlet wiring should be a minimum of

14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.

Electrical requirements

A 230/208-volt (197.6 min., 253 max.), 60-Hz, AC-only, 15-ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.

Electrical connection

Electrical ground is required on this air conditioner.

Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code (ANSI/NFPA 70 – latest edition) and local codes and ordinances. If a mating wall outlet is not available, it is the responsibility of the customer to have a properly grounded 3-prong outlet installed by a qualified electrician.

6

Page 6
Image 6
Whirlpool ACU124PK0 230/208-voltmodels with amperes up through, Electrical Requirements Continued, Do not use an adapter