Whirlpool AD0402XM0 manual Dehumidifier DE-ICERcontrol, Before calling for assistance

Models: AD0402XM0

1 12
Download 12 pages 6.98 Kb
Page 9
Image 9
Dehumidifier DE-ICER control

Dehumidifier DE-ICER control

The 48 Pint Model dehumidifier has a DE-ICERcontrol built into it. This feature allows you to operate the unit in room temperatures below 65°F(18.3”C). Without this de-icer control, the units evaporator coil would form frost that could prevent proper operation.

The DE-ICERcontrol senses frost build-up on the evaporator coils. When frost build-up is sensed it automatically shuts off the compressor, but allows the fan to continue running. The fan draws air across the coil which melts the frost. When the coil is defrosted, the DE-ICERcontrol automatically restarts the compressor and resumes dehumidifying.

This unit will not operate properly in room temperatures below 50°F (IOC).

If you need service or assistance, we suggest you follow these four steps:

1. Before calling for assistance...

Performance problems often result from little things you can find and fix yourself without tools of any kind.

It unit won’t opemte:

l

l

Is an extension cord being used? Do not use an

extension cord.

Are the coils iced or clogged with lint?

If unit ices up:

l Is humidity too low?

l Is room temperature below 65°F (18.3”C)? Coil will become iced over at low temperatures, ex-

/cept the 48 pint model which will operate down to 50°F (IOC].

l Is the dehumidifier correctly plugged into a live circuit with the proper voltage?

lIs the humidistat set to a position other than UNIT OFF? Try a dryer setting.

If water collects on the floor:

l Is unit reasonably level?

l Is hose or drain clogged or kinked?

lIsthe water pan overflowing? Pan must be prop- erly positioned.

Special dehumidifier needs:

l Annual inspection: Clean coils, inspect drain and hoses, oil the fan motor.

l Moving: When moving, keep the unit in an up- right position.

Remember-Pleaseinclude the model and serial number of your appliance when requesting serv- ice. Also, retain your sales slip and warranty to ver- ify your warranty status. Learn the benefits of using TECH-CARE8 service for maintaining the quality originally built into your WHIRLPOOLappliance.

l Have you checked the main fuse or circuit breaker box?

lIf a 48 pint model, is the temperature below 50°F (IOC)? The fan should run, but the unit will not dehumidify.

If unlt blows fuses or trips circuit breakers:

. Are correct time-delay fuses being used in the main fuse box?

2. If you need assistance?..

Call the Whirlpool COOL-LINE@J service as-

sistance telephone number.Dial free from:

Continental U.S. . . . . . . . . . . (800) 253-l 301

Michigan . . . . . . . . . . . . . . . (800) 632-2243 Alaska & Hawaii . . . . . . . . . (800) 253-1121

and talk with one of our trained Consultants. The Consultant can instruct you on how to obtain satis- factory operation from your appliance or, if serv- ice is necessary, recommend a qualified service company in your area.

9

Page 9
Image 9
Whirlpool AD0402XM0 manual Dehumidifier DE-ICERcontrol, Before calling for assistance, If you need assistance?