installation

Step 2 & 3 Connect to the elec- tricity supply

We recommend that the appliance is

connected by a competent person who is a member of a “Competent Person Scheme” & who will comply with the I.E.E. & local regulations.

Important: Ensure that you route all mains electrical cables well clear of any adjacent heat source, such as an oven or grill.

Warning: This appliance must be earthed.

For 60cm BI appliance:

1.Where a fixed connection is used, a device allowing the appliance to be isolated on all poles from the mains supply with a contact opening width of at least 3mm must be provided.

Use a 13 amp fuse.

2.A type HO5 V V-F cable must be used as the mains lead. The cross section must be a minimum of 1.5mm².

3.The mains terminal block is located

at the right hand rear of the top service panel.

4.Connect the cable to the terminal block & tighten the cable clamp.

5.Close the terminal box, ensuring the cover is engaged on the locking tabs.

For 70/90cm appliances:

1.The appliance must be installed using a double pole control unit of 32 ampere minimum capacity separation at all poles.

2.Access to the mains terminal is gained by opening the terminal block cover at the rear of the appliance (use a small flat bladed screwdriver).

3.Connection should be made with suitable twin & earth flexible cable, minimum 4mm² , which is suitable for use up to 25 amps.

4.First strip the wires, then push the cable through the cable clamp in the terminal block cover.

5.Connect the cable to the terminal block & tighten the cable clamp screw.

6.Close the terminal box, ensuring that the cover is engaged on the locking tabs.

Page 27
Image 27
Whirlpool AKP 803, AKP 801, AKZ 162 manual Connect to the elec- tricity supply, For 60cm BI appliance, For 70/90cm appliances