q ElectricalRequirements

q ElectricalRequirements

Electrical Shock Hazard

l Electrical ground is required on this appliance.

l Grounding wire must be connected to ground screw (located in lower right corner of unit) when air conditioner is in cabinet.

l DO NOT ground to a gas pipe.

l DO NOT modify the power supply cord. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

l DO NOT have a fuse in the neutral or grounding circuit.

l DO NOT use an extension cord with this appliance.

l Check with a qualified electrician if you are unsure whether the appliance is properly grounded.

Failure to follow these precautions could result in electrical shock, serious injury, or death.

OBSERVE ALL LOCAL CODES AND ORDINANCES.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.

NOTE: If codes permit, and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate and not interrupted by plastic, non-metallic gaskets, or other insulating materials.

To the right are electrical plug variations. Choose the plug that matches your unit’s plug. Then, use the chart below to find the voltage and ampere requirements for your unit, and the gauge of copper wire required for the receptacle wiring.

q RequerimientosElhtricos

Riesgo de Choque Electrico

l Este artefacto debe ser puesto a tierra.

9 El alambre de puesta a tierra debe ser conectado al tornillo de puesta a tierra (situado en la esquina derecha inferior del artefacto) cuando el acondicionador de aire est& en la caja mettilica.

l NO poner a tierra en una tuberia de gas.

l NO modificar el cable de suministro de energia. Si no ajusta bien en el tomacorriente, hater instalar un tomacorriente adecuado por un electricista calificado.

l NO usar un fusible en el circuit0 de puesta a tierra o neutral.

l NO SE DEBE USAR UN CABLE DE EXTENSION CON ESTE ARTEFACTO.

l Consultar con un electricista calificado para asegurarse de que el artefacto est& debidamente puesto a tierra.

El incumplimiento de estas precauciones puede resultar en choque el&trico, lesi6n grave o la muerte.

,

OBSERVAR TODOS LOS CODIGOS Y REGLAMENTOS LOCALES.

BAJO NINGUNA CIRCUNSTANCIA DEBE SACAR LA CLAVIJA DE PUESTA A TIERRA DEL CABLE DE ENERGIA ELECTRICA.

NOTA: Si 10s c6digos lo permiten y se usa un alambre de puesta a tierra separado, se recomienda que un electricista calificado determine si el trayecto de la puesta a tierra es adecuado y no Bsta interrumpido por empaquetaduras pl&sticas, no metalicas u otros materiales aisladores.

PLUG 1

2

3

4

REQUIREMENTS

l115 volt (103.5 min.-126.5 max.) l O-l 2 amperes

l15 amp time-delay fuse or circuit breaker.

l230 volt (207 min.-253 max.) or

l2301208 volt (197.6 min.-253 max.) l O-l 2 amperes

l15 amp time-delay fuse or circuit breaker.

l230 volt (207 min.-253 max.) or

l2301208 volt (197.6 min.-253 max.) l O-16 amperes

l 20 amp time-delay fuse or circuit breaker.

l230 volt (207 min.-253 max.) or

l230/208 volt (197.6 min.-253 max.) l O-24 amperes

l 30 amp time-delay fuse or circuit breaker.

COPPER WIRE

14gauge

14gauge

12gauge

IO gauge

La ilustraci6n a la derecha muestra varias configuraciones de enchufes el6ctricos. Seleccionar el que corresponda al enchufe de su artefacto. Luego usar la tabla que se incluye a continuaci6n para encontrar 10s requerimientos de voltaje y amperes para su artefacto y el calibre del alambre de cobre requerido para el alambrado del tomacorriente.

 

 

 

 

 

 

ALAMBRE

ENCHUFE

REQUERIMIENTOS

 

 

DE COBRE

1

l

115 voltios

(103.5

min.-126.5

m&x.)

Calibre

14

 

l

O-12 amperes

 

 

 

 

 

l

Disyuntor

o fusible

de acci6n

 

 

 

 

 

retardada

de 15 amp.

 

 

 

2

l

230 voltlos

(207 min.-253 max.) o

Calibre

14

 

l

2301208 voltios (197,6 min.-253

m&x.)

 

 

 

l

O-12 amperes

 

 

 

 

 

l

Disyuntor

o fusible

de acciOn

 

 

 

 

 

retardada

de 15 amp.

 

 

 

continlia en la p6gina 10