Operation instructions
6th sense mode
Press the th button, the unit enters 6th sense mode(fuzzy logic operation) directly regardless of
sense
the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature.
Operation mode and temperature are determined by indoor temperature
Heat pump models
| Indoor temperature |
| Operation mode |
| Target temperature | |||
| 21 | or below |
| HEATING |
| 22 |
|
|
|
|
|
|
|
|
|
|
|
| 21 |
| FAN ONLY |
|
|
|
| |
|
|
|
|
|
| Room temperature | ||
| 23 |
| DRY |
| decrease 1.5 | after | ||
|
|
| operate for 3 minutes | |||||
| Over 26 |
| COOLING |
| 26 |
|
| |
|
|
|
|
|
|
|
| |
Cooling only models |
|
|
|
|
|
| ||
| Indoor temperature |
| Operation mode | Target temperature | ||||
| 26 | or below |
| DRY | Room temperature |
| ||
|
| decrease 1.5 | after | |||||
|
|
|
|
|
| operate for 3 minutes | ||
| Over 26 |
| COOLING | 26 |
|
| ||
|
|
|
|
|
|
|
|
|
FAN
T
I
M
E
R
O
N
T
IM
ER
OF
F
CLOCK
ON
OFF
th
sense
MODE
| WIN | G |
S |
| |
|
|
|
| E | E | P |
S | L |
| ||
|
| |||
|
|
|
|
K
C
O
L
th
Button is ineffective in Jet mode.
sense
Note: Temperature, airflow and direction are controlled automatically in 6th mode. However, a decrease or rise of up to 2 can be set with the remote controller if you still feel uncomfortable.
What you can do in 6th sense mode
Your feeling
Uncomfortable because of unsuitable air flow volume.
Uncomfortable because of unsuitable flow direction.
button
FAN
| W | IN | G |
S |
| ||
|
| ||
|
|
|
adjustment procedure
Indoor fan speed alternates among High, Medium and Low each time this button is pressed.
Press it once, the vertical adjustment louver swings to change vertical airflow direction. Press it again, swings stops. For horizontal airflow direction, please refer to the previous page for details.
CLOCK button
You can adjust the real time by pressing CLOCK button, then
using and buttons to get the correct time, press CLOCK button again the real time is set.
9