Whirlpool AS12 manual Installation instructions, Connecting of the Cable Indoor Unit, Outdoor Unit

Models: AS12

1 23
Download 23 pages 50.08 Kb
Page 20
Image 20
4. Connecting of the Cable

Installation instructions

4. Connecting of the Cable

 Outdoor Unit Indoor Unit

Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection.

Note: For some models, it is necessary to remove the cabinet to connect to indoor unit terminal.

Cable Specifications Outdoor Unit

1). Remove the access door from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as the following.

2). Secure the power connecting cord onto the control board with cable clamp.

3). Reinstall the access door to the original position with the screw.

Front panel

Terminal (inside)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Cabinet

Indoor unit

Chassis

Access door

Terminal(inside)

Outdoor unit

Manual background The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.

Caution:

1.Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, refer to the circuit diagram posted on the inside of the access door .

2.Comfirm that the cable thickness is as specified in the power source specification. (See the cable specification table below)

3.Check the wires and make sure that they are all tightly fastened after cable connection.

4.Be sure to install an earth leakage circuit breaker in wet or moist area.

Cable Specifications

Capacity

Power cord

Power connecting cord

Main

(Btu/h)

 

 

 

 

 

 

power

Type

Normal cross

Type

Normal cross

 

supply

 

 

- sectional area

 

- sectional area

 

9K,12K

H05VV-F

1.0~1.5mm2X3

H07RN-F

1.5mm2X3

To indoor

18K

H05VV-F

2

H07RN-F

1.5mm

2

X3

To indoor

RVV

1.5~2.0mm X3

 

Attention:

Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect it in case of need. If not possible, connect appliance to a double-pole switching device with contact separation of at least 3 mm placed in an accessible position even after installation.