Models: 192906 BFG1F4034T3PV BFG1F4034T3PV 7K 195102 211456 BFG1F3030S3NOV BFG1H4040T3NOV 5K BFG2H5040T3NOV 7K 188424 211458 BFG2J5040T3NOV 7K 211454 221208 198984 BFG1J4040T3NOV 5K 195863 211304 BFG1F4034T3NOV 5K BFG1F5040T3PV BFG1H4040S3NOV 211360 4220 BFG1F5040T3PV 7K 192868 211289 BFG1F4040T3NOV 5K BFG1F5050T4NOV 145232 BFG2H4040T3NOV 7K BFG2H4040T3NOV E BFG2F4040S3PV ES 211450 SG1J5040T3NOV STP WP 5K SG1J5040T3NOV 5K 211462 BFG2H5040T3NOV E BFG1H5040T3NOV 5K 199748 211364 211446 BFG1F4040T3NOV BFG1F5040T3NOV STP WP5K LDO'06 216071 BFG1F4040T3NOV 7K BFG1F5040T3NOV 5K BFG1J4040T3NOV 7K 12307 187122 BFG1F4040T3NOV STP WP7K LDO'06 BFG1F3030T3NHV BFG2J5040T3NOV E 195207 211377 BFG1F4040T3NOV STP WP5K LDO'06 BFG1F3030T3PV BFG1F3030S3PV BFG2F4040T3NOV 7K BFG1F5040T3NOV 7K BFG2F4040T3NOV E

1 28
Download 28 pages 29.38 Kb
Page 4
Image 4
FIRE AND EXPLOSION HAZARD

Location RequirementsWARNING

FLAMMABLES

Flammable Vapors

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Site Location Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

Location Requirements

Manual backgroundWARNING

Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Doing so can result in death or carbon monoxide poisoning.

The Flame Lock™ Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-trap. The burning vapors literally “burn themselves out” without escaping back into the room. In the event of a flammable vapor incident, the Flame Lock™ Safety System shuts off the gas supply to the water heater’s burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will disable the water heater until the system is reset. Note: Not following these instructions and/or an inadequate air supply can cause the Flame Lock™ Safety System to disable the water heater. Please make required installation and venting/air supply changes prior to resetting the system.

IMPORTANT: This water heater has a resettable thermal switch installed as part of the Flame LockSafety System. DO NOT attempt to disable or modify this feature in any way.

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the area of the water heater, leave the area immediately and call the fire department from a neighbor’s home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical position on a level surface. DO NOT install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.