Models: 192906 BFG1F4034T3PV BFG1F4034T3PV 7K 195102 211456 BFG1F3030S3NOV BFG1H4040T3NOV 5K BFG2H5040T3NOV 7K 188424 211458 BFG2J5040T3NOV 7K 211454 221208 198984 BFG1J4040T3NOV 5K 195863 211304 BFG1F4034T3NOV 5K BFG1F5040T3PV BFG1H4040S3NOV 211360 4220 BFG1F5040T3PV 7K 192868 211289 BFG1F4040T3NOV 5K BFG1F5050T4NOV 145232 BFG2H4040T3NOV 7K BFG2H4040T3NOV E BFG2F4040S3PV ES 211450 SG1J5040T3NOV STP WP 5K SG1J5040T3NOV 5K 211462 BFG2H5040T3NOV E BFG1H5040T3NOV 5K 199748 211364 211446 BFG1F4040T3NOV BFG1F5040T3NOV STP WP5K LDO'06 216071 BFG1F4040T3NOV 7K BFG1F5040T3NOV 5K BFG1J4040T3NOV 7K 12307 187122 BFG1F4040T3NOV STP WP7K LDO'06 BFG1F3030T3NHV BFG2J5040T3NOV E 195207 211377 BFG1F4040T3NOV STP WP5K LDO'06 BFG1F3030T3PV BFG1F3030S3PV BFG2F4040T3NOV 7K BFG1F5040T3NOV 7K BFG2F4040T3NOV E

1 28
Download 28 pages 29.38 Kb
Page 11
Image 11
Chimney Connection

Chimney Connection

IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

The connector must be installed above the extreme bottom of the chimney to prevent potentially blocking the flue gases.

The connector must be firmly attached and sealed to prevent it from falling out.

To aid in removing the connector, a thimble or slip joint may be used.

The connector must not extend beyond the inner edge of the chimney as it may restrict the space between it and the opposite wall of the chimney (Figure 10).

Do not terminate the vent connector in a chimney that has not been certified for this purpose. Some local codes may prohibit the termination of vent connectors in a masonry chimney.

Vertical Exhaust Gas Vent

Vertical exhaust gas vents must be installed with U.L. listed type B vent pipe according to the vent manufacturer’s instructions and the terms of its listing.

It must be connected to the water heater’s drafthood by a listed vent connector or by directly originating at the drafthood opening.

Vertical gas vents must terminate with a listed cap or other roof assembly and be installed according to their manufacturer’s instructions.

Gas vents must be supported to prevent damage, joint separation, and maintain clearances to combustible materials (Figures 11 and 12).

IMPORTANT: This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases.

An unused chimney flue or masonry enclosure may be used as a passageway for the installation of a gas vent (Figure 12).

Common (combined) venting is allowable with vertical type B vent systems and lined masonry chimneys.

Figures 10-12 are examples of vent pipe system installations and may or may not be typical for your specific application. Consult the “National Fuel Gas Code”, NFPA 54, ANSI Z223.1-latest edition and the guidelines set forth by prevailing local codes.

Listed Lined

Chimney

Vertical Exhaust Gas VentManual backgroundManual background 2 ft. minimum above any

object within10 ft. horizontally

3 ft. minimum Manual background

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background*

Slope up

1/4 in.

per ft.

minimum

2 ft. minimum above any

3 ft. minimum object within10 ft. horizontally

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background*

**Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Vent connector slope up

1/4 in. per ft.

minimum

5 in. minimum

**

 

 

 

 

 

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background*

Slope up Manual backgroundManual background 1/4 in. Manual backgroundManual background per ft. Manual backgroundManual background minimumManual backgroundManual background

*Maintain vent pipe clearance requirements to local, state and/or the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

**NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances states that these chimneys are intended to be installed in accordance with the installation instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections.