PRODUCT DATA SHEETS

PRODUCT DATA SHEETS

Standard Interior Water Filtration System Model WFI-NL200/NL200

Tested and certified by NSF International against ANSI/NSF

Standard 42 for the reduction of Chlorine (Class I), Taste and Odor.

Capacity : 200 gallons (757 liters),

Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Chlorine, Taste/Odor

N/A

2.0 mg/L

N/A

0.02 mg/L

N/A

99%

994715

Cyst Interior Water Filtration System Model WFI-NLC200/NLC200

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 200 gallons (757 liters),

Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance Reduction

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

1.9 mg/L

N/A

0.06 mg/L

N/A

97%

994707

Particulate

N/A

108,667/mL*

N/A

45/mL

N/A

99.96%

994711

 

 

 

 

 

 

 

 

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Cyst

99.95%**

157,750/mL

55/mL

1.0/mL

99.9987%

99.9996%

994710

Turbidity

N/A

26 NTU

0.5 NTU

0.1 NTU

98.9%

99.5%

994710

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.015 mg/L

0.160 mg/L***

0.011 mg/L

0.001 mg/L

93.5%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.158 mg/L***

0.011 mg/L

0.001 mg/L

92.1%

99.3%

994709

 

 

 

 

 

 

 

 

It is essential that operational, maintenance, and filter replacement requirements be carried out for this product to perform as advertised.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Model NL200 Change cartridge at least every 6-9 months. Use replacement cartridge NL200, part# 8171413. 2001 suggested retail price of $29.95 U.S.A./$39.95 Canada.

Model NLC200 Change the cartridge at least every 6-9 months. Use replacement cartridge NLC200, part# 8171414. 2001 suggested retail price of $39.95 U.S.A./$49.95 Canada.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8° C)

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

®NSF is a registered trademark of NSF International.

23

Page 23
Image 23
Whirlpool GR2SHTXKQ00, ET8MTKXKQ00 Product Data Sheets, Standard Interior Water Filtration System Model WFI-NL200/NL200