Whirlpool GXW7336DXS Install RangeHood, ConnectVentSystem, A B C, For vented installations only

Models: GXW7330DXS GXW7336DXS

1 28
Download 28 pages 15.3 Kb
Page 8
Image 8
Install RangeHood

Install RangeHood

1.Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.

A

AB

C

A. Mounting screws

B. Mounting slots

C. Lower mounting screws

2.Remove the grease filter. See “Range Hood Care” section.

3.Level the range hood and tighten upper mounting screws.

4.Install 2 - 5 x 45 mm lower mounting screws and tighten.

ConnectVentSystem

1.Install transition on top of hood (if removed for shipping) with 2 - 3.5 x 9.5 mm sheet metal screws.

A

B

A. Vent transition

B. 3.5 x 9.5 mm screw

For vented installations only:

1.Fit vent system over transition piece.

2.Seal connection with clamps.

3.Check that back draft dampers work properly.

For non-vented (recirculating) installation only:

1.Assemble the air deflector with the duct cover bracket with 2 - assembly screws provided with the Recirculation Kit.

B ConnectVentSystem A

B

C

A. Vent cover bracket

B. 2.9 x 6.5 mm screws

C.Deflector

2.Measure from the bottom of the air deflector to the bottom of the hood outlet.

 

A

B

 

X

C

D

 

E

 

A. Air deflector

B. Vent clamp

C. X = length to cut vent duct

D. Vent duct

E. Exhaust outlet

3.Cut the duct to the measured size (X).

4.Remove the air deflector.

5.Slide the duct onto the bottom of the air deflector.

6.Place the assembled air deflector and duct over the exhaust outlet from the hood.

7.Reassemble the air deflector to the duct cover bracket with 2 assembly screws.

8.Seal connections with vent clamps.

8

Page 8
Image 8
Whirlpool GXW7336DXS, GXW7330DXS Install RangeHood, ConnectVentSystem, For vented installations only, B A B C