Whirlpool GZ7930XGS0 Vent system, requirements, Interior-mountedvent motor, Island location

Models: GZ7930XGS0

1 28
Download 28 pages 54.79 Kb
Page 6
Image 6
Vent system

Vent system

Interior-mounted vent motor

requirements

Installation requirements

Vent system installed under a concrete slab using PVC sewer pipe.

Venting system must terminate to the outside.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry- type wall caps

Do not use plastic or metal foil vent.

Vent work needed for installation is not supplied.

Wall cap is not provided with

Island location

down vent

6" (15.2 cm) round metal vent

wall

 

6" (15.2 cm)

 

round PVC

cap

 

sewer pipe

12" (30.5 cm)

16" (40.6 cm)

minimum

maximum

6" (15.2 cm)

 

 

round PVC

 

 

coupling

 

 

6" (15.2 cm)

Tightly pack

 

round 90°

gravel or sand

PVC sewer

completely

SBCCI

pipe elbow

around pipe.

transition

6" (15.2 cm) round metal vent

6" (15.2 cm) round PVC coupling

concrete slab

6" (15.2 cm) round PVC sewer pipe

6" (15.2 cm) round 90° PVC sewer pipe elbow

interior-mounted motor.

Determine which venting method to use. Vent system can extend through either the wall or roof.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

The size of the vent should be uniform.

Do not install two elbows together.

Use duct tape to seal all joints in the vent system.

Use caulking tape to seal the exterior wall or floor opening around cap.

Do not cut joist or stud. If vent cutout falls over a joist or stud, a supporting frame must be constructed.

Flexible metal vent is not recommended. If it is used, calculate each foot of flexible vent as two feet of rigid metal vent. Flexible elbows count twice as much as standard elbows.

NOTE: Make sure there is proper clearance within the wall or floor before making exhaust vent cutouts.

Recommended vent system length: For either interior-mounted or exterior-mounted blower installations, vent system length should not exceed the maximum lengths listed in the “Maximum length of vent system” chart. (See this page for Interior-mounted vent motor; page 9 for exterior- mounted vent motor.)

6

Built-in cabinet locations

down vent

rear vent

left vent

right vent

Optional vent system installed under a concrete slab into a window well.

Do not vent a gas cooktop into a window well.

12" (30.5 cm)

6" (15.2 cm) round

transition

minimum

 

PVC sewer pipe

6" (15.2 cm)

 

 

 

 

 

 

concrete

 

round metal vent

wall

 

 

6" (15.2 cm)

 

slab

 

cap

 

 

round PVC

 

 

 

 

 

 

 

coupling

 

 

 

 

6" (15.2 cm)

 

 

 

 

round sewer

 

 

 

 

pipe

window

 

 

 

6" (15.2 cm) round

 

 

 

90° PVC sewer

well

 

 

 

 

 

 

pipe elbow

6" (15.2 cm)

 

 

Tightly pack

 

 

 

min.

6" (15.2 cm) gravel or sand

 

round PVC

completely

 

 

coupling

SBCCI

 

around pipe.

 

 

 

Seal the space between the outside of wall cap inlet inside of PVC coupling with caulking metal.

Maximum length of vent system

Vent

Length

6" (15.2 cm) round

35 feet (8.9 m)

3-1/4" x 10"

35 feet (8.9 m)

(8.3 cm x 25.4 cm)

 

For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24" (61 cm) of straight vent between any two elbows. Do not install two elbows together. It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 6" (15.2 cm) round vent as soon as possible.

Determining the length of system you need:

To calculate the length of system you need, add the equivalent feet for each vent piece that will be needed. See example for 6"

(15.2 cm) round vent system.

Page 6
Image 6
Whirlpool GZ7930XGS0 Vent system, Interior-mountedvent motor, Installation requirements, Maximum length of vent system