Recommended standard

 

fittings

support leg

90° elbow =

45° elbow =

4. Attach support legs to side of

5 ft. (1.5 m)

2.5 ft. (0.8 m)

 

 

downdraft vent with two screws in

 

 

 

 

each leg. Do not tighten screws.

cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs.

7. Attach 10" (25.4 cm) round vent collar plate (supplied with exterior blower system) to front of downdraft vent using 4 hex washer nuts.

Installation steps

1. Put on gloves and safety glasses. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton. Remove all shipping materials, tape and protective film from downdraft vent and blower box.

over counter support arm

2. Attach the left side and right side overcounter support brackets to the downdraft. Use 1 screw with each bracket.

WARNING

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

5. Carefully insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets rest gently on countertop.

8. Remove the 2 Phillips-head screws attaching the wiring box cover and remove cover. Remove either the back or bottom knockout and install conduit connector.

NOTE: Power supply cable needed between exterior blower assembly and blower box is not provided.

9. Determine the location where the exterior blower box will be located. Cut opening in roof or wall for vent system to exterior blower. Install exterior blower according to instructions supplied with the blower kit.

Wall Installations:

Use caulking compound between mounting flange and wall.

Roof Installations:

• Follow standard roofing

procedures.

• The flashing sheet should be

centered over the roof opening.

• Lower edge of flashing should lie

on top of shingles and upper edge

underneath shingles.

level

end cap

mark

• Seal assembly between roof, fan

and flashing with roofing mastic

to prevent leaks.

3. Attach the left side and right side end caps to the downdraft. Use 1 screw with each end cap.

6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust position of legs until downdraft is level vertically. Use a pencil to mark the top of each leg on face of downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on

10

Page 10
Image 10
Whirlpool GZ7930XGS0 installation instructions Recommended standard Fittings