16. Turn the control knob on side of vent to check the operation and speed of blower.

If blower does not operate:

Check that filter or filters are pressed in as far as they will go.

Check that circuit breaker is not tripped or house fuse blown.

Disconnect power. Check that wire connections have been made correctly.

Reconnect power.

17. Connect vent system to blower. Vent system must end with a wall or roof cap. Use duct tape to seal all joints.

18. Install cooktop according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by 3/8" (9.5 mm).

To get the most efficient use from your new retractable downdraft vent, read the Use and Care Information section on page 12.

Keep Installation Instructions

and Use and Care

Information close by for

easy reference.

Exterior-mounted vent motor

KIRD and YKIRD

MODELS ONLY

NOTE: Exterior-mounted vent motor installations require exterior blower system, Model No. KPEC992M [900 cfm (25.5 m3/m)], available from your dealer or authorized parts supplier.

IMPORTANT: Exterior blower Model No. KPEU722M [1200 cfm (34.0 m3/3)] cannot be used with this retractable downdraft vent system.

Installation requirements

Island location

Built-in cabinet location

Roof venting

10" (25.4 cm) round vent

Maximum length of vent system

Vent

Length

10" (25.4 cm) round

40 ft. (12.2 m)

 

 

It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 10" (25.4 cm) round vent as soon as possible.

Determining the length of system you need:

To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 10"

(25.4 cm) round vent system.

10" (25.4 cm) round vent system

Vent length is given as a general reference only. For a longer vent run, or smaller vent system, contact a qualified and trained vent installer. Check with local codes for makeup air requirements, if any.

For best performance, use no more

than three 90° elbows. If more than

Built-in cabinet location one elbow is used, make sure that there is a minimum of 24 inches

(61 cm) of straight vent between any two elbows. Do not install two elbows together.

Maximum length = 40 ft. (12.2 m)

2 - 90 elbows

= 10

ft. (3.05 m)

10 ft. (3 m) straight

= 10

ft. (3.05 m)

 

 

 

Length of 10"

 

 

(25.4 cm) system

= 20 ft. (6.1 m)

NOTE: The exterior-mounted vent motor requires a separate wiring cable that should be installed at the same time the vent work is installed.

left vent

right vent

9

Page 9
Image 9
Whirlpool GZ7930XGS0 installation instructions Kird and Ykird, 10 25.4 cm round vent system