Make Electrical Connection

WARNING

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction and in Canada.

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge solid copper wire.

Electrically ground oven.

Failure to follow these instructions can result in death, fire, or electrical shock.

This oven is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare) ground wire twisted together.

1.

Disconnect power.

2.

Feed the flexible conduit from the oven through the opening

 

in the cabinet.

3.

Remove junction box cover, if it is present.

4.

Install a UL listed or CSA approved conduit connector to the

A

B

C

D

A. Cable from home power supply B. Black wires

C. Red wires

D. 4-wire flexible conduit from oven

E. Junction box

E

F

G

H

I

F. White wires

G. UL listed wire connectors H. Green (or bare) ground wires

I. UL listed or CSA approved conduit connector

junction box.

A

A. UL listed or CSA approved conduit connector

5.Route the flexible conduit from the oven to the junction box through a UL listed or CSA approved conduit connector.

6.Tighten screws on conduit connector.

7.See “Electrical Connection Options Chart” to complete installation for your type of electrical connection.

Electrical Connection Options Chart

If your home has:

Go to section:

4-wire

4-wire Cable from Home

 

Power Supply

 

½"

 

(1.3 cm)

3-wire

3-wire Cable from Home

 

Power Supply

½"

(1.3 cm)

1.Connect the 2 black wires (B) together using a UL listed wire connector.

2.Connect the 2 red wires (C) together using a UL listed wire connector.

3.Untwist white wire from green (or bare) ground wire coming from the oven.

4.Connect the 2 white wires (F) together using a UL listed wire connector.

5.Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector.

6.Install junction box cover.

3-Wire Cable from Home Power Supply

IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a 3-wire connection.

A

 

B

 

C

G

 

H

D

E

I

F

A. Cable from home power supply B. Junction box

C. Black wires D. White wires

F.4-wire flexible conduit from oven

G. Red wires

H. UL listed wire connectors

E. Green (or bare) ground wire (from oven)

I. UL listed or CSA approved conduit connector

5

Page 5