Whirlpool RH2600, RH2 300, RH2000 installation instructions I‘I I’1I’ J,“11, Panel C

Models: RH2600 RH2 300

1 7
Download 7 pages 9.41 Kb
Page 4
Image 4
\,I‘I

\,I‘I

,I’1I’,

J,“11

centerline,

W Determine and clearly mark a vertical centerline on the woli and cabinet in the area the vent opening will be mode.

fromWwaii (not cabinet

frame)

I

t

centerline

7.

To wire through fop, mark o line

7-l /2” from the right of the centerline on the underside of the cabinet. Mark the point on this line that is l-3/8” from bock wall. Drill a l-l /4” diameter hole through the cabinet at this point.

centerline

To wire through rear, mark a line 7-l /2” from the right of the centerline on the wall. Mark the point on this line that is 64-5/a” from the floor (or l-3/8” from underside of cabinet).

Drill a l-l /4” diameter hole through wall at this point.

cabinet

5-l/h” 5-114”

l from wail, not cabinet frame

\

To make a 4” x I0.-l/2” rectangle on the underside of cabinet top and bottom:

a. Mark lines 1” and 5” from the bock wall on the centerline of the underside of cabinet.

b. Mark lines 5-l /4” to the right and left of the centerline on the underside of cabinet.

c. Use sober and keyhole sows to cut a rectangular opening for duct.

d. Repeat steps a-cfor the underside of the top of the cabinet.

If venting through the wall with 3- l/4” x 10” rectangular duct -

To make a 4” x 10-l /2” rectangle in the wall:

a. Measure from floor 65-7/a” and 62-3/8” (or l/8” and 3-5/8” down from underside of cabinet) and mark on the centerline on the bock wall.

b. Mark lines 5-l /4” to the right and left of the centerline on the underside of cabinet.

c. Use sober and keyhole sows to cut Q rectangular opening for duct.

Mark 5-l/8” and 5-7/a” in from bock wall along the centerline on underside of cabinet. Use these points as centers to draw 7-l /8” circles on underside of cabinet.

Use a sober saw to cut the openings for the ductwork. Repeat for the underside of the top of the cabinet. This will create slotted openings.

l from wail, not

 

cabinet

frame

I

\

To transition from a 3- l/4” x 10” rectangular duct to a 7” round duct and vent through the roof -

Start by making a 4” x 1O-l /2” rectangle on the underside of cabinet bottom:

a. Mark lines 1” and 5” from the bock wall on the centerline of the underside of cabinet.

Now, make a 7-l /8” x 7-5/a” slot on the underside of the cabinet top:

b. Mark lines 5-l /4” to the right and left of the centerline on the underside of cabinet.

c. Use sober and keyhole sows to cut a rectangular opening for duct.

i,

1

cutoutscabinet k,

d. Mark lines 4-l /2” and 5” from the bock wall on the centerline on the underside of the top of cabinet.

e. Draw two 7-l /8” circles using the marks mode in step d as center points.

f. Use sober and keyhole sows to cut a slotted (oval) opening to make installing 7” round duct easier.

Panel C

Page 4
Image 4
Whirlpool RH2600, RH2 300, RH2000 installation instructions I‘I I’1I’ J,“11, Panel C