Whirlpool RH8330, RH8336 Venting through the roof, Numbers correspond to steps, Panel C

Models: RH8330 RH8336

1 7
Download 7 pages 57.07 Kb
Page 4
Image 4
Numbers correspond to steps.

Numbers correspond to steps.

10.10a.

11.11a.

7. 8. 9.

cabinet cutouts

5-1/4" 10.10a.13.13a.Excessive Weight HazardUse two or more people to move and install range hood.5"

5-1/4" 1"

5.To vent through the roof with

3-1/4" x 10" rectangular vent, mark a line 1" and 5" from the back wall on the underside of the cabinet. Mark lines 5-1/4" to the right and left of the centerline on the underside of cabinet that connect the lines just drawn. Use a keyhole saw or saber saw to cut a rectangular opening for the vent system. Repeat for the underside of the top of the cabinet.

To vent through wall with 3-1/4" x 10" rectangular vent, measure 1/8" and

3-5/8" down from underside of cabinet and mark on back wall. Measure and mark a line 5-1/4" to right and left of centerline, connecting the two lines. Use a keyhole saw or saber saw to cut a rectangular opening for the vent system.

13.13a.

16.16a.

12.12a.

17.17a.

18.18a.

8.Remove three screws that hold light cover panel in place.

Remove light panel and set aside.

wire retainer indents

wire retainer

blower wiring connector plug

remove

screw

9. Carefully disconnect blower wiring connector from terminal box

connector plug. Snap blower wire retainer out of blower housing. Carefully set blower on protective covering.

Note: It is much easier to remove the vent knockouts and to install the range hood with the blower removed.

12.

Remove the screw holding the terminal box cover. Remove cover.

Failure to follow this instruction can result in back or other injury.WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to follow this instruction can result in back or other injury.

keyhole slot

13. Venting through the roof

Lift the range hood into final position and center. Mark on the underside of cabinet the location of the four keyhole mounting slots and the wiring knockout. On some cabinets, filler blocks may need to be added for range hood to attach to cabinet. Set range hood aside on a protected surface.

14. Do Not turn on power until installation is complete. Run

wiring through wall or cabinet according to the National Electrical Code and local codes and ordinances.

keyhole slot outline

screw

15. Start screws into neck area of each of the four keyhole

mounting screw slots marked on the cabinet bottom.

To vent through the roof with round vent, a 3-1/4" x 10" to round transition piece must be used.

6.Install vent system through the vent opening in upper cabinet or

wall. Complete venting system according to method needed. See Venting requirements. Use caulking to seal exterior wall or roof opening.

holes

Venting through the roof

wiring knockout

roof vent knockout

16. Lift range hood into position, and feed electrical wire

through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the range hood toward the wall so that the screws are in the neck of the keyhole slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Make sure that damper blade rotates up and down freely.

screws

filters

7. Set range hood on protective cover. Insert finger into hole in filter

and pull back and down to remove. Repeat for other filter.

wiring knockout

10.Remove the roof vent knockout. Remove top or rear

wiring knockout as needed.

damper blade (remove if roof cap Panel C has damper blade)

11. Attach exhaust vent connection to range hood.

Check that the damper blade rotates up and down freely, if used.

terminal box

3" Manual background

5"

17. Reinstall blower back into position. Snap blower wire

retainer back into blower housing indents. Reconnect the blower wiring connector back into the terminal box connector plug.

Panel C

Page 4
Image 4