Numbers correspond to steps.
10.10a.
11.11a.
7. 8. 9.
cabinet cutouts
5.To vent through the roof with
To vent through wall with
13.13a.
16.16a.
12.12a.
17.17a.
18.18a.
8.Remove three screws that hold light cover panel in place.
Remove light panel and set aside.
wire retainer indents
wire retainer
blower wiring connector plug
remove
screw
9. Carefully disconnect blower wiring connector from terminal box
connector plug. Snap blower wire retainer out of blower housing. Carefully set blower on protective covering.
Note: It is much easier to remove the vent knockouts and to install the range hood with the blower removed.
12.
Remove the screw holding the terminal box cover. Remove cover.
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to follow this instruction can result in back or other injury.
keyhole slot
13.
Lift the range hood into final position and center. Mark on the underside of cabinet the location of the four keyhole mounting slots and the wiring knockout. On some cabinets, filler blocks may need to be added for range hood to attach to cabinet. Set range hood aside on a protected surface.
14. Do Not turn on power until installation is complete. Run
wiring through wall or cabinet according to the National Electrical Code and local codes and ordinances.
keyhole slot outline
screw
15. Start screws into neck area of each of the four keyhole
mounting screw slots marked on the cabinet bottom.
To vent through the roof with round vent, a
6.Install vent system through the vent opening in upper cabinet or
wall. Complete venting system according to method needed. See Venting requirements. Use caulking to seal exterior wall or roof opening.
holes
Venting through the roof
wiring knockout
roof vent knockout
16. Lift range hood into position, and feed electrical wire
through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the range hood toward the wall so that the screws are in the neck of the keyhole slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Make sure that damper blade rotates up and down freely.
screws
filters
7. Set range hood on protective cover. Insert finger into hole in filter
and pull back and down to remove. Repeat for other filter.
wiring knockout
10.Remove the roof vent knockout. Remove top or rear
wiring knockout as needed.
damper blade (remove if roof cap has damper blade)
11. Attach exhaust vent connection to range hood.
Check that the damper blade rotates up and down freely, if used.
terminal box
3"
5"
17. Reinstall blower back into position. Snap blower wire
retainer back into blower housing indents. Reconnect the blower wiring connector back into the terminal box connector plug.