Whirlpool UXT5236AYS Venting Requirements, Installation Clearances, Cold Weather Installations

Models: UXT5236AYS UXT5230AYB UXT5230AYS

1 32
Download 32 pages 50.34 Kb
Page 5
Image 5

Installation Clearances

C

B

D

A

E

A. 18" (45.7 cm) min. clearance - upper cabinet to countertop

B. 24" (61.0 cm) to 30" (76.2 cm) suggested max. - bottom of range hood to cooking surface

C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm) models.

D. 13" (33.0 cm) cabinet depth

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

Roof Venting

Wall Venting

 

B

A

A

B

 

C

C

 

E. 36" (91.4 cm) base cabinet height

Venting Requirements

Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use a 7" (17.8 cm) round metal vent or a 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent, depending on your installation requirement. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps or duct tape to seal all joints in the vent system.

The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

A. 7" (17.8 cm) round vent through roof (purchased separately).

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the roof (purchased separately).

B. Roof cap with damper (purchased separately)

C. 24" (61.0 cm) min. to

30" (76.2 cm) max. above the cooking surface

A. 7" (17.8 cm) round vent out the top and through the wall (purchased separately).

3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent through the wall or out the top (purchased separately).

B. Wall cap with damper (purchased separately)

C. 24" (61.0 cm) min. to

30" (76.2 cm) max. above the cooking surface

5

Page 5
Image 5
Whirlpool UXT5236AYS, UXT5230AYS Venting Requirements, Installation Clearances, Cold Weather Installations, Makeup Air

UXT5236AYS, UXT5230AYB, UXT5230AYS specifications

The Whirlpool UXT5230AYS, UXT5230AYB, and UXT5236AYS are three highly regarded under-cabinet range hoods that blend contemporary design with cutting-edge technology, aiming to enhance the efficiency and aesthetics of modern kitchens. Each model is designed to provide powerful ventilation while maintaining a streamlined appearance, complementing various kitchen styles.

One of the standout features of these range hoods is their robust airflow capacity, which effectively removes smoke, odors, and steam produced while cooking. With a maximum CFM (cubic feet per minute) rating of 190, these models ensure that your kitchen remains fresh and free from lingering smells. The adjustable fan speeds offer the flexibility needed to match the ventilation power with the intensity of your cooking, ensuring optimal performance for both light and heavy-duty culinary tasks.

The UXT5230AYS and UXT5230AYB models come equipped with a convenient push-button control system. This user-friendly interface makes it easy to adjust fan speeds and turn the hood's lights on and off, providing hassle-free operation while cooking. Additionally, the UXT5236AYS features similar controls but with an enhanced design aesthetic to cater to various consumer preferences.

Lighting is crucial in the kitchen, and these range hoods do not disappoint with their bright, energy-efficient LED lighting. This lighting casts a clear beam over your cooking surfaces, making food preparation safer and more enjoyable. The longevity of LED lights minimizes the need for frequent replacements, making these hoods a cost-effective choice in the long run.

Maintenance has been simplified as well, with stainless steel baffle filters that are both durable and easy to clean. These filters capture grease effectively while adding a sophisticated touch to the hood’s design. They are dishwasher safe, allowing for effortless cleaning without the risk of damage.

In terms of installation, the UXT5230AYS and UXT5230AYB models have a slim profile, making them ideal for kitchens with limited space. Each unit is designed to fit comfortably under cabinets while providing sufficient coverage over cooking surfaces.

Overall, the Whirlpool UXT5230AYS, UXT5230AYB, and UXT5236AYS range hoods stand out in terms of performance, design, and functionality. They are excellent choices for homeowners looking to enhance their kitchen's ventilation and overall efficiency while enjoying the benefits of modern technology and stylish aesthetics.