Whirlpool W10130752A installation instructions Complete Conversion, To Convert Oven Burner

Models: W10130752A

1 16
Download 16 pages 47 Kb
Page 13
Image 13
To Convert Oven Burner

2.Locate LP gas orifice spuds for top burners in the bag con- taining literature included with the range. Three LP gas spuds are stamped “88” and one “96.”

3.Remove natural gas orifice spuds using a 7mm combination wrench.

4.Install LP gas orifice spuds.

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 power burner. Spud size/location remain the same.

A

B

A.Spud

B.Holder

Std burner 88

Std burner 88

Power burner 96

Std burner 88

To Convert Oven Burner

1.Open oven door and remove oven racks, oven tray, flame spreader and set aside.

2.Lift oven burner. The orifice spud is behind the oven burner air shutter.

A

A. Air shutter

3.Locate LP gas orifice spud stamped “56” in literature package supplied with range.

4.Use a ³⁄₈" combination wrench and remove the natural gas orifice spud.

5.Install the number “56” LP gas spud.

AComplete Conversion

A. LP oven orifice spud stamped with “56”

IMPORTANT: Do not over tighten.

6.Place natural gas oven burner spud in plastic parts bag along with natural gas cooktop burner spuds for future use and keep with bag containing literature.

7.Reinstall oven burner.

8.Reinstall oven racks, oven tray and flame spreader.

5.Place the natural gas orifice spuds in the parts bag for future use and keep with bag containing literature.

6.Reinstall burners, burner caps and burner grates.

Complete Conversion

1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2.Turn the manual shutoff valve in the gas supply line to the open position.

3.Refer to the “Check Operation” section for proper burner ignition, operation, and burner flame adjustments.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¹⁄₄" to ¹⁄₂" (6.4 mm to 13 mm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip.

4.Close the broiler door and turn the knob to “OFF”.

5.Refer to the “Complete Installation” section to complete this procedure.