Whirlpool W10130752A Natural Gas Conversion, To Convert Gas Pressure Regulator

Models: W10130752A

1 16
Download 16 pages 47 Kb
Page 14
Image 14
Natural Gas Conversion

Natural Gas Conversion

Manual backgroundWARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to rear range foot.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

To Convert Gas Pressure Regulator

1.Ensure that the manual shutoff valve is in the closed position.

A

C

B

A. Shutoff valve in “closed” position

B. Gas supply line

C. To range

2.Unplug or disconnect power.

3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

NOTE: Do not remove the spring beneath the cap.

4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.

5.Turn the cap over so that N or NAT is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grates, burner caps, and burners.

Manual background A

B

A. Burner cap

B.Burner

2.Locate the natural gas orifice spuds for the top burners in the bag containing literature included with the range. Three natural gas spuds are stamped “149” and one “165.”

3.Remove the LP gas orifice spuds using a 7mm combination wrench.

14

Page 14
Image 14
Whirlpool W10130752A Natural Gas Conversion, To Convert Gas Pressure Regulator, To Convert Surface Burners