3.Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.
AD
E
B
F
C
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C. ¾" (1.9 cm) UL listed strain relief
D. Center
E. Neutral ground wire
F. Neutral wire (white or center wire)
4.Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5.Tighten strain relief screw.
6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
7.You have completed your electrical connection. Now go to “Venting Requirements.”
1.Loosen or remove center
2.Connect neutral wire (white or center wire) of power supply cord to the center,
| C |
A |
|
B | D |
| |
| E |
A. External ground conductor screw
B. Neutral ground wire
C. Center
D. Neutral wire (white or center wire)
E. ³⁄₄" (1.9 cm) UL listed strain relief
3.Connect the other wires to outer terminal block screws. Tighten screws.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
6.You have completed your electrical connection. Now go to “Venting Requirements.”
3-wire connection: Power supply cord
Use where local codes permit connecting
BDE
A
CG F
A.
B.
C.Neutral prong
D.Spade terminals with up turned ends
E.³⁄₄" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
3-wire connection: Direct wire
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using
1" .5cm) (2
3¹⁄₂" (8.9 cm)
11