Whirlpool 99044504A Installation Instructions, Prepare Location, Determine Wiring Hole Location

Models: 99044504A W10240546A

1 24
Download 24 pages 25.47 Kb
Page 7
Image 7
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Prepare Location

NOTE: For vented installations, it is recommended that the vent system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

1.For vented installations, determine which venting method to use: roof or wall.

2.Select a flat surface for assembling the range hood. Place covering over that surface.

Prepare LocationWARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

3.Using 2 or more people, lift the range hood onto covered surface.

4.If cabinet has recessed bottom, add wood filler strips on each side. Install screws to attach filler strips in locations shown.

Wood filler strips (recessed cabinet bottoms only)

3" (7.6 cm)

7 ¹⁄₂"

2" (5.1 cm)

from wall,

(19 cm)

not cabinet

 

 

frame

Centerline

To wire through rear wall:

Mark a line 7½" (19.0 cm) from the right of the centerline on the wall. Mark the point on this line that is ¾" (1.9 cm) from underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole through wall at this point.

To wire through rear wall: ³⁄₄" (1.9 cm)

7 ¹⁄₂"

(19 cm)

Cabinet

bottom

3" (7.6 cm)

Wall

Determine Wiring Hole Location

Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole. See Step 2 for wiring hole location instructions. Either wiring hole can be used.

1.Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made.

A Determine Wiring Hole Location

A.Centerline

2.To wire through top:

Mark a line 7½" (19.0 cm) from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 2" (5.0 cm) from back wall. Drill a 1¼" (3.0 cm) diameter hole through the cabinet at this point.

Centerline

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

4.Repeat steps 1-3 for the underside of the top of the cabinet.

Cabinet cutouts

 

 

*1¹/₂" (3.8 cm)

*5¹/₂"

 

5¹/₄"

(14 cm)

(13.3 cm)

 

 

 

 

5¹/₄"

 

(13.3 cm)

*From wall, not cabinet frame

7

Page 7
Image 7