Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH
■A 120 Volt, 60 Hz., AC only,
■If the house has aluminum wiring follow the procedure below:
1.Connect a section of solid copper wire to the pigtail leads.
2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.
■Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the hood.
■Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.
INSTALLATION INSTRUCTIONS
Prepare Location
NOTE: For vented installations, it is recommended that the vent system be installed before hood is installed.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
1.For vented installations, determine which venting method to use: roof or wall.
2.Select a flat surface for assembling the range hood. Place covering over that surface.
Determine Wiring Hole Location
Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole. See Step 2 for wiring hole location instructions. Either wiring hole can be used.
1.Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made.
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
3.Using 2 or more people, lift the range hood onto covered surface.
4.If cabinet has recessed bottom, add wood filler strips on each side. Install screws to attach filler strips in locations shown.
Wood filler strips (recessed cabinet bottoms only)
3" (7.6 cm)
A
A.Centerline
2.To wire through top:
Mark a line 7½" (19.0 cm) from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 2" (5.0 cm) from back wall. Drill a 1¼" (3.0 cm) diameter hole through the cabinet at this point.
Cabinet |
bottom |
3" (7.6 cm) | Wall |
7 ¹⁄₂" | 2" (5.1 cm) | |
from wall, | ||
(19 cm) | ||
not cabinet | ||
| ||
| frame |
Centerline
7