Whirlpool W10240580A, 99044505A Roof Venting, Wall Venting, To wire through rear wall

Models: 99044505A W10240580A

1 28
Download 28 pages 23.9 Kb
Page 8
Image 8
To wire through rear wall:

To wire through rear wall:

Mark a line 7½" (19.0 cm) from the right of the centerline on the wall. Mark the point on this line that is ¾" (1.9 cm) from underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole through wall at this point.

Roof Venting ³⁄₄" (1.9 cm)

7 ¹⁄₂"

(19 cm)

Centerline

Style 2 - Cut Openings for 7" (17.8 cm) Round Vent System

Roof Venting

To make a 7¹⁄₄" (18.4 cm) circle on the underside of the cabinet top and bottom:

1.Mark a centerline on the underside of the cabinet bottom.

2.Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet.

3.Draw a circle using a compass or 7¹⁄₄" (18.4 cm) circle template.

4.Use saber or keyhole saw to cut a 7¹⁄₄" (18.4 cm) diameter opening.

5.Repeat steps 1-4 for the underside of the top of the cabinet.

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

4.Repeat steps 1-3 for the underside of the top of the cabinet.

*5"

 

(12.7 cm)

7 ¹/₄" (18.4 cm) diam.

 

cabinet cutouts

*From wall, not cabinet frame

Cabinet cutouts

 

 

*1¹/₂" (3.8 cm)

*5¹/₂"

 

5¹/₄"

(14 cm)

(13.3 cm)

 

 

 

 

5¹/₄"

 

(13.3 cm)

*From wall, not cabinet frame

Wall Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:

1.Make 2 lines by measuring from floor 65⁷⁄₈" (167.3 cm) and 62³⁄₈" (158.4 cm) or ¹⁄₈" (3.2 mm) and 3⁵⁄₈" (9.2 cm) down from underside of cabinet and mark on the centerline on the back wall.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the wall.

3.Use saber or keyhole saw to cut a rectangular opening in the wall for the vent.

Centerline

Cabinet

front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

¹⁄₈"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.2 mm)

 

 

 

 

 

 

 

 

 

⁵⁄₈"

 

 

 

 

 

 

 

3

 

 

 

 

 

5 ¹⁄₄"

(9.2 cm)

 

 

 

 

(13.3 cm)

 

 

 

 

 

 

Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent to 7" (17.8 cm) Round Vent Transition

Roof Venting

To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the underside of cabinet bottom:

1.Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for

vent.

*1¹/₂" (3.8 cm)

*5¹/₂"

(14 cm) 5¹/₄"

5¹/₄" (13.3 cm)

(13.3 cm)

*From wall, not cabinet frame

8

Page 8
Image 8
Whirlpool W10240580A, 99044505A installation instructions Roof Venting, Wall Venting, To wire through rear wall