Whirlpool W10403811C wire connection Power Supply Cord, wire Connection Direct Wire, A B C D

Models: W10403811C

1 16
Download 16 pages 60.11 Kb
Page 10
Image 10
3-wire connection: Power Supply Cord

4.Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw and ground-link section. The ground wire must be attached first.

5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

A

F

 

 

B

C

E

 

 

D

A. 10–32 hex nut

D. Green ground wire

B. Ground-link screw

E. Neutral (center) wire

C. Line 2 (red)

F. Line 1 (black)

6.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

7.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8.Tighten strain relief screws.

9.Replace terminal block access cover.

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.

1.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A Direct Wire Installation: Copper or Aluminum Wire³⁄₈"4-wire Connection: Direct WireManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

C

Manual backgroundManual backgroundManual backgroundD

A. Terminal block

B.Ground-link screw

C.UL listed strain relief

D.Power supply cord wires - large opening

2.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

A

E

 

B

D

 

 

C

A. 10–32 hex nut

D. Neutral (white) wire

B. Line 2 (red)

E. Line 1 (black)

C.Ground-link screw

3.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

4.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

5.Tighten strain relief screws.

6.Replace terminal block access cover.

Direct Wire Installation: Copper or Aluminum Wire

This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection.

1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back ³⁄₈" (1.0 cm) from the end of each wire.

³⁄₈"

(1.0 cm)

Manual background 3" (7.6 cm)

2.Allow enough slack in the wire to easily attach the wiring terminal block.

3.Complete electrical connection according to your type of electrical supply (4-wire or 3-wire connection).

4-wire Connection: Direct Wire

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the neutral

10

Page 10
Image 10
Whirlpool W10403811C wire connection Power Supply Cord, Direct Wire Installation Copper or Aluminum Wire, A B C D