Whirlpool W10459123B Complete Conversion, Natural Gas Conversion, To Convert Oven Burner, B A C

Models: W10459123B

1 16
Download 16 pages 1.89 Kb
Page 14
Image 14

To Convert Oven Burner

1.Open the oven door and remove oven racks, oven tray and flame spreader and set aside.

2.Lift oven burner. The orifice spud is behind the oven burner air shutter.

A

B

A. Oven burner

B. Air shutter

3.Locate LP gas orifice spud stamped “58” in the package containing literature supplied with the range.

4.Use a ³⁄₈" combination wrench and remove the Natural gas orifice spud.

5.Install the number “58” LP gas spud. IMPORTANT: Do not overtighten.

A

A. LP oven orifice spud stamped with “58”

6.Place Natural gas oven burner spud in plastic parts bag along with Natural gas cooktop burner spuds for future use and keep with the package containing literature.

7.Reinstall oven burner.

8.Reinstall oven racks, oven tray and flame spreader.

Complete Conversion

1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.

2.Turn the manual shutoff valve in the gas supply line to the “open” position.

3.Refer to “Check Operation of Cooktop Burners” in the “Electronic Ignition System” section for proper burner ignition, operation and burner flame adjustments.

IMPORTANT: You may have to adjust the “Lo” setting for each cooktop burner.

Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.6 cm to 1.3 cm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip.

4.Close the oven door and turn the knob to the “OFF” position.

5.Refer to the “Complete Installation” section to complete this procedure.

Natural Gas Conversion

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Install anti-tip bracket to floor or wall per installation instructions.

Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.

Re-engage anti-tip bracket if range is moved.

Do not operate range without anti-tip bracket installed and engaged.

Failure to follow these instructions can result in death or serious burns to children and adults.

To Convert Gas Pressure Regulator

1.Turn manual shutoff valve to the “closed” position.

B

A

C

A. Gas supply line

B. Manual shutoff valve “closed” position

C. To range

2.Unplug range or disconnect power.

3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.

A

A. Gas pressure regulator

IMPORTANT: Do not remove the gas pressure regulator.

14

Page 14
Image 14
Whirlpool W10459123B installation instructions Complete Conversion, Natural Gas Conversion, To Convert Oven Burner, B A C