Whirlpool W10459123B installation instructions To Convert Surface Burners

Models: W10459123B

1 16
Download 16 pages 1.89 Kb
Page 15
Image 15

4.Remove the cap from the gas pressure regulator using a flat-blade screwdriver.

NOTE: Do not remove the spring beneath the cap.

A

A.Cap

5.Turn the cap over so that N or NAT is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grate, burner caps and burners.

A

B

A. Burner cap

B.Burner

2.Locate the Natural gas orifice spuds for top burners in the package containing literature included with the range. Two Natural gas spuds are stamped “149” and two “125.”

3.Remove the LP gas orifice spuds using a 7 mm combination wrench.

4.Install the Natural gas orifice spuds using a 7 mm combination wrench.

A

B

A.Spud

B.Holder

NOTE: This range is equipped with 2 standard burners and 2 super burners. Spud size and location remain the same.

Standard

Super

Burner 125

Burner 149

Super

Standard

Burner 149

Burner 125

5.Place LP gas orifice spuds in the parts bag for future use and keep with the package containing literature.

6.Reinstall burners, burner caps and burner grates.

15

Page 15
Image 15
Whirlpool W10459123B installation instructions To Convert Surface Burners