Whirlpool W10477533B To Convert Surface Burners, Inlet pressure, to LP gas, to Natural gas

Models: W10477533B

1 32
Download 32 pages 2.63 Kb
Page 15
Image 15
Std Burner 149

4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.

NOTE: Make sure sealing washer remains in the same position.

A

A.Cap

5.To convert to Natural gas, unscrew the plastic adjustment screw by hand, turn it over, and screw it in again.

Inlet pressure

Inlet pressure

to LP gas

to Natural gas

 

A

 

B

180ºC

A.Cap

B.Sealing washer

C.Adjustment screw

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grate, burner caps and burners.

Super Burner 165 A

Manual background B

A. Burner cap

B.Burner

2.Locate the Natural gas orifice spuds for top burners in the package containing literature included with the range. Three Natural gas spuds are stamped “149” and one “165.”

3.Remove the LP gas orifice spuds using a 7 mm combination wrench.

4.Install the Natural gas orifice spuds using a 7 mm combination wrench.

A

B

A.Spud

B.Holder

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 super burner. Spud size and location remain the same.

For models with 4 standard burners:

Std Burner 149

Std Burner 149

Std Burner 149

Std Burner 149

For models with 3 standard burners and 1 super burner:

Std Burner 149

Std Burner 149

Super Burner 165

Std Burner 149

5.Place LP gas orifice spuds in the parts bag for future use and keep with the package containing literature.

6.Reinstall burners, burner caps and burner grates.

15

Page 15
Image 15
Whirlpool W10477533B To Convert Surface Burners, Inlet pressure, to LP gas, to Natural gas, Std Burner, Super Burner