Whirlpool W10526071A Natural Gas Conversion, To Convert Surface Burners, A C B D, B A C

Models: W10526071A

1 40
Download 40 pages 23.75 Kb
Page 15
Image 15
To Convert Surface Burners

6.Position the broil burner against the roof of the oven cavity and attach with screw.

AB

A. Broil burner orifice hood

B. Broil burner

5.Replace the Natural gas orifice spud with the correct LP gas orifice spud. See the “LP Gas Orifice Spud Chart.”

6.Replace burner base and hand tighten the screws.

7.Replace burner cap.

8.Repeat steps 1 through 7 for the remaining burners.

9.Place Natural gas orifice spuds in plastic parts bag for future use and keep with literature package.

10.Replace burner grates.

11.Complete installation. See “Make Gas Connection” and “Electronic Ignition System” sections.

Checking for proper cooktop burner flame is very important. The small inner cone should have a very distinct blue flame ¼" to ½" long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip.

IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner. See “Adjust Flame Height” in the “Electronic Ignition System” section.

To Convert Surface Burners

1.If the burner grates are installed, remove them.

2.Remove the burner caps.

3.Using a Phillips or Torx® screwdriver, remove the burner base.

A A

Natural Gas Conversion C Manual background

B Manual backgroundManual backgroundManual backgroundManual backgroundManual background

Manual backgroundD

A. Burner cap

C. Burner base screws

B. Gas tube opening

D. Burner base

4.Apply masking tape to the end of a ⁹⁄₃₂" (7.0 mm) nut driver to help hold the Natural gas orifice spud in the nut driver while changing it. Press nut driver down onto the Natural gas orifice spud and remove by turning it counterclockwise and lifting out. Set the Natural gas orifice spud aside.

A

A. Natural gas orifice spud

Use the following chart for correct LP gas orifice spud for each burner. Refer to the model/serial rating plate behind the control panel for proper sizing of LP gas orifice spuds for each burner location.

LP Gas Orifice Spud Chart

Burner Rating

Color

Number

4,000 BTU

Blue

64L

7,000 BTU

Black

81L

9,100 BTU

Green

97L

14,000 BTU

Red

114L

 

 

 

Natural Gas Conversion

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Install anti-tip bracket to floor or wall per installation instructions.

Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.

Re-engage anti-tip bracket if range is moved.

Do not operate range without anti-tip bracket installed and engaged.

Failure to follow these instructions can result in death or serious burns to children and adults.

1.Turn manual shutoff valve to the closed position.

Manual backgroundB

A

C

A. To range

B. Shutoff valve (closed position)

C. Gas supply line

2.Unplug range or disconnect power.

15

Page 15
Image 15
Whirlpool W10526071A installation instructions Natural Gas Conversion, To Convert Surface Burners, A C B D, B A C