GAS CONVERSIONS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install
Slide range back so rear range foot is engaged in the slot of the
Do not operate range without
Failure to follow these instructions can result in death or serious burns to children and adults.
To Convert Gas Pressure Regulator
1.Turn manual shutoff valve to the “closed” position.
B
A
C
A. Gas supply line
B. Manual shutoff valve “closed” position
C. To range
2.Unplug range or disconnect power.
3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
14