4.Remove the cap from the gas pressure regulator using a
NOTE: Do not remove the spring beneath the cap.
A
A.Cap
5.Turn the cap over so that N or NAT is visible.
A
A. Cap
6.Reinstall the cap.
To Convert Surface Burners
1.Remove burner grate, burner caps and burners.
A
B
A. Burner cap
B.Burner
2.Locate the Natural gas orifice spuds for top burners in the package containing literature included with the range. Two Natural gas spuds are stamped “149” and two “125.”
3.Remove the LP gas orifice spuds using a 7 mm combination wrench.
4.Install the Natural gas orifice spuds using a 7 mm combination wrench.
A
B
A.Spud
B.Holder
NOTE: This range is equipped with 2 standard burners and 2 super burners. Spud size and location remain the same.
Standard | Super |
Burner 125 | Burner 149 |
Super | Standard |
Burner 149 | Burner 125 |
5.Place LP gas orifice spuds in the parts bag for future use and keep with the package containing literature.
6.Reinstall burners, burner caps and burner grates.