3.Determine and mark centerline of the cutout space. The mounting can be installed on either the left side or right side of the cutout. Position mounting bracket against the wall in the cutout so that the
B
Centerline
A
A. 7⁷⁄₈" (20 cm)
B. Bracket
4.Drill two ¹⁄₈" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See the following illustrations.
Floor Mounting
Rear position | Front position | Diagonal (2 options) |
Wall Mounting
5.Using the Phillips screwdriver, mount
6.Move range close enough to opening to allow for final gas and electrical connections. Remove shipping base, cardboard or hardboard from under range.
7.Move range into its final location, making sure rear leveling leg slides into
8.Move range forward onto shipping base, cardboard or hardboard to continue installing the range using the following installation instructions.
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range to the existing gas line. Your connections may be different, according to the supply line type, size and location.
1.Apply
2.Using a pipe wrench to tighten, connect the gas supply to the range.
B
C
| A |
| D |
| E |
| F |
| G |
A. Pressure regulator | D. Union |
connection fitting | E. Nipple |
B. 90° elbow | F. Manual shutoff valve |
C. Black iron pipe | G. ½" or ¾" gas pipe |
Typical flexible connection
1.Apply
2.Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters.