1.Remove cover from thermostat by gripping the base in one hand. Use the other hand to pull gently at the top or bottom of the cover.

2.Carefully remove the shipping protective packing from the switch.

3.Pull wires through the opening in the thermostat base and connect wires beneath the terminal screws. (see Fig. 2 & 3).

4.Push excess wiring back into wall and plug hole with fire resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

5.Position thermostat base over hole in wall and mark mounting hole location on wall.

6.Drill mounting hole.

7.Fasten base loosely to wall using mounting screws. Place a level against the top of the thermostat base, adjust until level, and tighten mounting screws to secure base. If holes in wall are too large and do not allow you to tighten the mounting screws securely, use plastic exansion plugs.

8.Snap the cover on the thermostat base and set temperature lever to desired setpoint.

9.Turn on electrical power to the system.

 

Heat

 

 

Anticipator

 

 

(adjustable)

 

W

THERMOSTAT

R

SYSTEM

 

 

Heating

 

Hot

System

 

 

 

 

24VAC

120VAC

 

 

Neutral

Figure 2. Wiring Diagram

Terminal

screws

10 10

15

 

 

 

15

20

 

 

 

20

25

 

 

 

25

30

 

 

 

30

 

Thermostat

Cover

Thermostat

Mounting

Cover

Base

Base

screws

 

 

Figure 3. Parts of Thermostat

ADJUSTMENT & MAINTENANCE

ADJUSTING HEAT ANTICIPATOR

CAUTION

The adjustable heat anticipator WILL BURN OUT if 25vAC is applied directly to the thermostat because of incorrect wiring or by shorting out the primary control during testing. This may cause personal injury and/or property damage.

This thermostat is equipped with an adjustable heat anticipator and was preset at the factory to provide satisfactory operation of the heating system under normal conditions. If additional adjustments are necessary, they may be made as follows (see Fig. 4).

1.

Remove thermostat cover.

2.

If heat cycle is too long, set heat anticipator to a slightly

 

lower dial setting (1/2 division).

3.If heat cycle is too short, set heat anticipator to a slightly higher dial setting (1/2 division).

4.Replace thermostat cover.

. .

.

.

. .

Move this lever to

Arrow points to theadjust heat matched current rating

of the primary control

anticipator

Figure 4. Anticipator Adjustment

3

Page 3
Image 3
White Rodgers 1E30(W), 1F30(W) Adjustment & Maintenance, Attaching Thermostat, Adjusting Heat Anticipator

1E30(W), 1F30(W) specifications

White Rodgers is renowned for its innovative thermostats and control systems, offering a range of products designed to enhance energy efficiency and comfort in residential and commercial spaces. The models 1F30(W), 1F30(W), 1E30(W), and 1E30(W) exemplify their commitment to quality and advanced technology.

The White Rodgers 1F30 series is a programmable thermostat that benefits homeowners with its user-friendly interface and customizable features. One of its main highlights is its ability to program settings for different times of the day and days of the week, allowing users to adjust temperatures based on their specific schedules. This helps optimize energy consumption, reducing unnecessary heating or cooling when it’s not needed.

Key features of the 1F30 models include a large, easy-to-read display which simplifies temperature adjustments and settings. The models boast intuitive controls that make programming a straightforward process even for users who may not be technologically savvy. Enhanced control means better comfort, providing consistent temperatures throughout the home.

The 1E30 series shares many characteristics with the 1F30 models but is typically aimed at economical and efficient heating systems. With similar programming functionalities, it offers flexibility and efficiency without sacrificing performance. The 1E30 series is particularly noted for its compatibility with various HVAC systems, making it a versatile option for homeowners with diverse heating and cooling needs.

Both the 1F30 and 1E30 series utilize advanced technology such as digital temperature sensing, which ensures accurate readings and reduces fluctuations, creating a more stable indoor environment. Additionally, features like auto-changeover and energy-saving programs help users maintain their desired comfort levels while minimizing energy costs.

In terms of installation, White Rodgers thermostats are designed to be user-friendly, with straightforward wiring and a simple setup process. This means that many homeowners can install the thermostat themselves, saving time and installation costs.

Overall, the White Rodgers 1F30 and 1E30 series bring together ease of use, innovative technology, and energy efficiency. These thermostats stand out for their ability to provide comfort while being mindful of energy consumption. With their modern features, they effectively cater to the needs of today's homeowners who value efficiency, reliability, and user-centric designs. In an era where smart home technology is becoming increasingly important, White Rodgers continues to lead by providing solutions that are not just functional but also seamlessly integrate into daily life.