CONFIGURATION MENU
Press the SYSTEM button until OFF is displayed, then press the (_ and (_ simultaneously
INSTALLER/CONFIGURATION MENU
| Press | Displayed | Press Q or Q |
|
|
|
|
|
|
|
| ||
Step | Button(s) | (Factory Default) | to select |
|
| Comments |
|
| |||||
1 | System | MS 2 | SS1, HP2, | HP1 | Selects Single stage, | or Heat Pump | |||||||
|
|
|
|
|
| (Single stage or | |||||||
2 | System | 7d | 5d, 0d | Selects | Programs | Per Week | |||||||
3 | System | PRG 4 | PRG | 2 | Selects Programmable | Periods | (PRG 2 = 2 | ||||||
|
|
|
|
|
| programmable periods; PRG 4 = 4 programmable periods) | |||||||
4 | System | 4:00 HOLD | 0:15 | to 4:00 | Selects Temporary | Program Override Time | |||||||
|
|
| (increments | of 15 minutes) |
|
|
|
|
|
|
|
| |
5 | System | EMR | OFF |
| Selects Energy | Management | Recovery | OFF or ON | |||||
|
| (ON) |
|
|
|
|
|
|
|
|
|
|
|
6 | System | FA |
| SL |
| Selects | Fast or Slow Cycle | Selection | |||||
7 | System | CL |
| CL |
| Selects Compressor | Lockout CL OFF or ON | ||||||
|
| (OFF) | (ON) |
|
|
|
|
|
|
|
|
| |
8 | System | CDL | CDL |
| Selects Backlight | Display |
| ||||||
|
| (ON) | (OFF) |
|
|
|
|
|
|
|
|
| |
9 | System | FA |
| FA |
| Selects Fast | Second Stage ON or OFF | ||||||
|
| (ON) | (OFF) |
|
|
|
|
|
|
|
|
| |
10 | System | 0 FLTR | Selects | filter replacement | run | time | |||||||
11 | System | 0°F | 4 LO to 4 HI | Selects Temperature | Display | Adjustment | 4 LO to 4 HI | ||||||
|
| (Room Temperature) |
|
|
|
|
|
|
|
|
|
|
|
12 | System | °F |
| °C |
| Selects temperature | display | F° or °C selection | |||||
13 | System | AU On | OFF |
| Selects AUTO | Mode ON or OFF | |||||||
14 | System | LR | LR 62 | to | LR89 | Selects | Limited | HEAT | range | ||||
|
| (90) |
|
|
|
|
|
|
|
|
|
|
|
15 | System | LR | LR 46 to LR 82 | Selects | Limited | COOL | range | ||||||
|
| (45) |
|
|
|
|
|
|
|
|
|
|
|
16 | System | CA |
| CA |
|
| Feature | Not Available |
| ||||
|
| (OFF) | (ON) |
|
|
|
|
|
|
|
|
| |
17 | System | _ | (ON) |
| Selects Keypad | Lockout |
| ||||||
|
| (OFF) |
|
|
|
|
|
|
|
|
|
|
|
18 | System | 0 | 001 | to 999 | Selects Keypad | lockout | combination | number | |||||
|
|
|
|
|
| Press System to set code |
| ||||||
19 | Run |
|
|
|
| Returns to the OFF position |
programmable, SYSTEM button selection will skip Programmable periods (item 3), programmable hold time (item 4) and EMR (item 5).
3)Programmable Periods - This control can be configured for 4 or 2 programmable periods. The display indicates "PRG 4" in the display as default. The programmable periods can be toggled to "PRG 2" by pressing the (E) or (_ keys.
4)Select Temporary Program Override Time
of time you select on this option. Your choices are 0:15 to 4:00 hours in 15 minute increments.
Example:
1.You have selected 3:00 hours for the Temporary Pro- gram Override time period.
2.With the thermostat set to Heat or Cool, press (_ or C)
to set the temperature to your preference. The thermostat will maintain this temperature setting for 3 hours with "HOLD" blinking to remind you it is in Temporary Hold. After 3 hours, the thermostat will go back to the program temperature and "HOLD" will no longer blink or display.
6