Installation
Select Configuration Options
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
Enter Menu
SYSTEM
Home
|
| Menu Navigation |
|
Press |
|
|
|
and hold | Press | for next. Press | to go back |
for 3 seconds |
|
|
|
Configuration Menu
Menu Screen | Displayed | Press | or |
|
Number | (Factory Default) | to select options |
| |
|
|
|
|
|
01 | Sleep |
| On | Select Sleep Timer On or OFF |
| (OFF) |
|
| If selected OFF, skip to menu screen 04 |
|
|
|
| |
02 | h | 1 to 12 | Select 1 to 12 hours for Sleep Timer On. | |
| (8) |
|
| See Sleep Timer section on page 3 |
|
|
|
|
|
03 | CS |
| On | Select Cool Savings Feature On or OFF |
| (OFF) |
|
| If selected OFF, skip to menu screen 06 |
|
|
|
|
|
04 | CS |
| 1 to 6 | Select 1 to 6 for Cool Savings Feature On |
| (3) |
|
| See Cool Savings section on page 3 |
|
|
|
|
|
05 | CR |
| SL | Select Adjustable Anticipation, cycle rate for Heat Pump, Heat |
| (FA) |
|
| and Cool. See table below |
|
|
|
|
|
06 | CR Aux |
| FA | Select Adjustable Anticipation, cycle rate for Aux./Emer Heat. |
| (FA) |
|
| See table below |
|
|
|
|
|
07 | CL |
| On | Select Compressor Lockout OFF or On. When selected On, |
| (OFF) |
|
| the thermostat will wait 5 minutes before turning the |
|
|
|
| compressor on. |
|
|
|
|
|
08 | L |
| OFF | Select Display Light On of OFF. When selected On and the “C” |
| (On) |
|
| terminal is connected, the backlight will stay on continuously. |
|
|
|
| When OFF the backlight will come on for a short time when any |
|
|
|
| key is pressed. |
|
|
|
| |
09 | Room Temp | 4 LO to | Select room temperature display for 4o higher or 4o lower than | |
| (0) |
| 4 HI | the actual temperature |
|
|
|
|
|
10 | oF |
| oC | Select oF or oC Display (temperature displayed in Fahrenheit or |
|
|
|
| Celsius) |
|
|
|
|
|
11 | FH |
| OFF | Select fast second stage On or OFF |
| (On) |
|
|
|
|
|
|
|
|
12 | Change Filter |
| On | Select filter maintenance indicator OFF or On. |
| (OFF) |
|
| If selected OFF, item B will be skipped |
|
|
|
| |
13 | Change Filter | 25 to 1975 | Select 25 to 1975 hours for Change Filter reminder | |
| (200 h) |
|
| See Change Filter reminder section on page 3 |
|
|
|
|
|
To exit the menu: Set the system switch to Cool or Heat. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.
Select Cycle Rate – The cycle rate can be adjusted to keep the heat or cool on longer or shorter to match the temperature response of the home with your heating and cooling system.
MODE | Fast | Slow |
| (FA) | (SL) |
Heat Pump | 1.2oF | 1.7oF |
Aux./Emer Heat | .8oF | 1.2oF |
5