White Rodgers 1F89EZ-0251 Select Configuration Options, Configuration Menu, Installation

Models: 1F89EZ-0251

1 8
Download 8 pages 40.48 Kb
Page 5
Image 5
Select Configuration Options

Installation

Select Configuration Options

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.

Enter Menu

SYSTEM

Home

 

 

Menu Navigation

 

Press

 

 

 

and hold

Press

for next. Press

to go back

for 3 seconds

 

 

 

Configuration Menu

Menu Screen

Displayed

Press

or

 

Number

(Factory Default)

to select options

 

 

 

 

 

 

01

Sleep

 

On

Select Sleep Timer On or OFF

 

(OFF)

 

 

If selected OFF, skip to menu screen 04

 

 

 

 

02

h

1 to 12

Select 1 to 12 hours for Sleep Timer On.

 

(8)

 

 

See Sleep Timer section on page 3

 

 

 

 

 

03

CS

 

On

Select Cool Savings Feature On or OFF

 

(OFF)

 

 

If selected OFF, skip to menu screen 06

 

 

 

 

 

04

CS

 

1 to 6

Select 1 to 6 for Cool Savings Feature On

 

(3)

 

 

See Cool Savings section on page 3

 

 

 

 

 

05

CR

 

SL

Select Adjustable Anticipation, cycle rate for Heat Pump, Heat

 

(FA)

 

 

and Cool. See table below

 

 

 

 

 

06

CR Aux

 

FA

Select Adjustable Anticipation, cycle rate for Aux./Emer Heat.

 

(FA)

 

 

See table below

 

 

 

 

 

07

CL

 

On

Select Compressor Lockout OFF or On. When selected On,

 

(OFF)

 

 

the thermostat will wait 5 minutes before turning the

 

 

 

 

compressor on.

 

 

 

 

 

08

L

 

OFF

Select Display Light On of OFF. When selected On and the “C”

 

(On)

 

 

terminal is connected, the backlight will stay on continuously.

 

 

 

 

When OFF the backlight will come on for a short time when any

 

 

 

 

key is pressed.

 

 

 

 

09

Room Temp

4 LO to

Select room temperature display for 4o higher or 4o lower than

 

(0)

 

4 HI

the actual temperature

 

 

 

 

 

10

oF

 

oC

Select oF or oC Display (temperature displayed in Fahrenheit or

 

 

 

 

Celsius)

 

 

 

 

 

11

FH

 

OFF

Select fast second stage On or OFF

 

(On)

 

 

 

 

 

 

 

 

12

Change Filter

 

On

Select filter maintenance indicator OFF or On.

 

(OFF)

 

 

If selected OFF, item B will be skipped

 

 

 

 

13

Change Filter

25 to 1975

Select 25 to 1975 hours for Change Filter reminder

 

(200 h)

 

 

See Change Filter reminder section on page 3

 

 

 

 

 

To exit the menu: Set the system switch to Cool or Heat. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.

Select Cycle Rate – The cycle rate can be adjusted to keep the heat or cool on longer or shorter to match the temperature response of the home with your heating and cooling system.

MODE

Fast

Slow

 

(FA)

(SL)

Heat Pump

1.2oF

1.7oF

Aux./Emer Heat

.8oF

1.2oF

5

Page 5
Image 5