White Rodgers 1F89EZ-0251 installation instructions Technical Data, Specifications

Models: 1F89EZ-0251

1 8
Download 8 pages 40.48 Kb
Page 7
Image 7
Technical Data

Technical Data

Figure 2. Typical wiring diagram for single transformer systems

O/B

Y

G

W2

C **

Changeover

Relay* Compressor Fan Aux/Emergency

Contactor Relay Heat Relay

(Stage 2)

*Changeover Relay is energized in COOL when O/B switch is in the “O” position Changeover Relay is energized in HEAT when O/B switch is in the “B” position

**The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.

THERMOSTAT

 

L

R

SYSTEM

 

 

 

SYSTEM

 

 

 

 

 

 

 

MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

Hot

24 VAC

 

 

 

 

 

 

 

 

 

 

 

120 VAC

Neutral

TRANSFORMER

(Class II Current Limited)

THERMOSTAT APPLICATION GUIDE

Thermostat

Thermostat

Maximum

Configuration

Stages

Applications

Options

Heat/Cool

 

 

 

 

Heat Pump 1

Single Stage Compres-

 

Single Stage

sor Heat Pump Systems

2/1

Compressor Heat

- with Aux./Emergency

 

Pump (HP)

Heat

 

 

 

 

ATTENTION!

This product does not contain mercury. However, this product may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded.

Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container. Refer to www.white-rodgers.com for location to send the product containing mercury.

Specifications

Electrical Rating:

 

 

Battery Power or Hardwire

20 to 30 VAC, 50/60 Hz or DC

Terminal Load

1.5 A per terminal, 2.5 A maximum all terminals combined

Setpoint Range

45° to 90°F (7° to 32°C)

Differential

Fast

Slow

Heat Pump

1.2°F

1.7°F

Aux./Emer Heat

.8°F

1.2°F

Operating Ambient

32° to +105°F (0° to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40° to +150°F (-40° to +65°C)

Dimensions Thermostat

3-3/4” H x 4-3/4” W x 1-1/2” D

7

Page 7
Image 7
White Rodgers 1F89EZ-0251 installation instructions Technical Data, Specifications