White Rodgers 1F89EZ-0251 installation instructions Troubleshooting, Reset Operation

Models: 1F89EZ-0251

1 8
Download 8 pages 40.48 Kb
Page 6
Image 6
Troubleshooting

Troubleshooting

Reset Operation

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you may need to reset the thermostat. To reset, the System Switch must be in Cool,

HEAT, or EMER. Simultaneously hold the Reset Operation and Manual background buttons

for approximately 10 seconds until the display goes blank. If the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Symptom

Possible Cause

Corrective Action

 

 

 

No Heat/No Cool/No Fan

1. Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2. Furnace power switch to OFF.

Turn switch to ON.

 

3. Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

panel loose or not properly installed.

interlock or door switch.

 

 

 

No Heat

1. System Switch not set to Heat.

Set System Switch to Heat and raise setpoint above room

 

 

temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system

 

 

3. Heating System requires service or

Diagnostic: Set System Switch to Heat and raise the

 

thermostat requires replacement.

setpoint above room temperature. Within a five minutes

 

 

the thermostat should make a soft click sound. This sound

 

 

usually indicates the thermostat is operating properly. If

 

 

the thermostat does not click, try the reset operation listed

 

 

above. If the thermostat does not click after being reset

 

 

contact your heating and cooling service person or place of

 

 

purchase for a replacement. If the thermostat clicks, con-

 

 

tact the furnace manufacturer or a service person to verify

 

 

the heating system is operating correctly.

 

 

 

No Cool

1. System Switch not set to Cool.

Set System Switch to Cool and lower setpoint below room

 

 

temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system.

Same procedure as diagnostic for No Heat condition

 

3. Cooling System requires service or

except set the thermostat to Cool and lower the setpoint

 

thermostat requires replacement

below the room temperature. There may be up to a five

 

 

minute delay before the thermostat clicks in Cooling if the

 

 

compressor lock-out option is selected in the configuration

 

 

menu.

 

 

 

Heat, Cool or Fan Runs

1. Possible short in wiring.

Check each wire connection to verify they are not shorted

Constantly

2. Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3. Possible short in Heat/Cool/Fan

under terminal screws. Try resetting the thermostat as

 

system.

described below. If the condition persists, the manufacturer

 

4. Fan Switch set to Fan On.

of your system or service person can instruct you on how

 

 

to test the Heat/Cool system for correct operation. If the

 

 

system operates correctly, replace the thermostat.

 

 

 

Furnace Cycles Too Fast

1. The location of the thermostat and/or

The cycle rate adjustment can be found in the configuration

or Too Slow (narrow or

the size of the Heating System may be

menu. If an acceptable cycle rate is not achieved using the

wide temperature swing)

influencing the cycle rate.

FA (Fast) or SL (Slow) adjustment contact a local service

 

 

person for additional suggestions.

 

 

 

Cooling Cycles Too Fast

1. The location of the thermostat and/or

The cycle rate for cooling is fixed and can not be adjusted.

or Too Slow (narrow

the size of the Cooling System may

Contact a local service person for suggestions.

or wide temperature

be influencing the cycle rate.

 

swing)

 

 

 

 

 

Thermostat Setting and

1. Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees as listed

Thermometer Disagree

requires adjustment.

in the Configuration Menu. No other adjustment is possible.

 

 

 

Blank Display and/or

1. Voltage Spike or Static Discharge.

If a voltage spike or static discharge occurs use the Reset

Keypad Not Responding

 

Operation listed above.

 

 

 