SPECIFICATIONS

SPECIFICATIONS

ELECTRICAL DATA

Shipping Temperature Range:

Electrical Rating:

-40°F to 150°F

17 to 30v AC 50/60 Hz.

 

 

0.05 to 1.5 Amps

APPLICATIONS

1.5 Amps Maximum Total Load (All terminals

For use with:

combined)

• Standard heat/cool, heat-only, or cool-only sys-

 

 

tems

Anticipation:

Electric heat systems

Heating 2 to 40

Gas or oil fired systems

Cooling 4 to 40 }Reference Values

Gas systems with intermittent ignition devices

 

 

(I.I.D.) and/or vent dampers

THERMAL DATA

Do not use with:

Setpoint Temperature Range:

Multi-stage systems

40° F to 99°F (4°C to 37° C)

• Heat pump systems

Operating Ambient Temperature Range:

• Systems exceeding 30v AC and 1.5 Amps

32°F to 105°F

ACCESSORIES

Operating Humidity Range:

Thermostat Guard W. R. Part No. F29-0198 (clear) or

0 to 90% RH (non-condensing)

F29-0238 (opaque)

INSTALLATION

NEW INSTALLATION

You should program the thermostat with batteries installed before attaching on subbase. See OPERA- TION GUIDE for programming instructions.

SELECT THERMOSTAT LOCATION

Proper location insures that the thermostat will provide a comfortable building temperature. Observe the following general rules when selecting a location:

1.Locate thermostat about 5 ft. above the floor.

2.Install thermostat on a partitioning wall, not on an outside wall.

3.Never expose thermostat to direct light from lamps, sun, fireplaces or any temperature radiating equip- ment.

4.Avoid locations close to windows, adjoining outside walls, or doors that lead outside.

5.Avoid locations close to air registers or in the direct path of air from them.

6.Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.

7.Never locate thermostat in a room that normally warmer or cooler than the rest of the building.

8.Avoid locations with poor air circulation, such as behind doors or in alcoves.

ROUTE WIRES TO LOCATION

NOTE

All wiring must conform with local and national electrical codes and ordinances.

1.Probe for obstructions in partition before drilling 1/2" hole in wall at selected location. Take up quarter round and drill a small guide hole for sighting (see fig. 1). From basement, drill 3/4" hole in partition floor next to guide hole. In basementless buildings, drill 1/ 2" hole through ceiling and into partition from above.

2.Through this hole drop a light chain, or 6" chain attached to a strong cord. Snag cord in basement with hooked wire. In basementless buildings, drop cord through hole in ceiling and down partitioning; snag cord at the thermostat location.

3.Attach thermostat wire to cord and pull cable through hole in wall so that 6" of wire protrudes.

1/2" HOLE FOR

THERMOSTAT WIRE

STOUT CORD WITH 6"

CHAIN ATTACHED

APPROXIMATELY

BASEBOARD5 FEET

STRIP MOLDING

1/4" GUIDE HOLE

FOR SIGHTING

QUARTER ROUND

REMOVED

3/4" HOLE IN FLOOR OF PARTITION

HOOKED WIRE FOR SNAGGING CHAIN

Figure 1. Routing Thermostat Wires

2

Page 2
Image 2
White Rodgers 1F90W-51 Specifications, Installation New Installation, Select Thermostat Location, Route Wires To Location

1F90W-51 specifications

The White Rodgers 1F90W-51 is a sophisticated thermostat designed for modern heating and cooling systems, offering homeowners a blend of convenience, energy efficiency, and advanced technology. This programmable thermostat is well-regarded for its user-friendly features and ease of installation, making it a popular choice among DIY enthusiasts and professionals alike.

One of the standout features of the White Rodgers 1F90W-51 is its ability to provide precise temperature control. It supports a 7-day programming schedule, allowing users to set different temperatures for each day of the week, maximizing comfort while minimizing energy usage. This feature is particularly beneficial for families with varying schedules, enabling them to maintain optimal home temperatures when they are present and reduce heating or cooling when the house is empty.

The 1F90W-51 incorporates advanced technology that allows for compatibility with a wide range of HVAC systems, including conventional heating and cooling setups, heat pumps, and even multi-stage systems. The thermostat's digital display makes it easy for users to read and adjust settings, while its intuitive interface simplifies programming and operation.

In terms of efficiency, the White Rodgers 1F90W-51 is designed to help homeowners save on energy bills. By allowing for precise temperature adjustments and programmable schedules, it encourages users to optimize their heating and cooling usage. This not only protects the environment by reducing energy consumption but also translates to cost savings over time.

Another notable characteristic of the 1F90W-51 is its built-in temperature hold feature, which allows users to override the programmed settings temporarily. This is useful for occasions when unexpected changes in schedule may require a quick adjustment without the need to reprogram the entire unit.

In addition to functionality, the White Rodgers 1F90W-51 boasts a sleek design that blends seamlessly into any home décor. Its compact size and classic appearance allow it to fit well in various locations throughout the house.

Overall, the White Rodgers 1F90W-51 is a reliable and feature-rich thermostat that provides users with the tools needed to enhance their home comfort while remaining conscious of energy consumption. Its combination of programmability, compatibility, and user-friendly design makes it a top choice for those seeking an efficient and effective climate control solution.