White Rodgers 1F95-1291 specifications Wiring Diagrams, 24 VAC, 120 VAC, Neutral, Transformer

Models: 1F95-1291

1 16
Download 16 pages 34.94 Kb
Page 4
Image 4
24 VAC

WIRING DIAGRAMS

Figure 4 – Humidity and Sensors

HM

DHM

 

 

Humidification Terminal,

De-energizes on call for

Energizes on call for

Dehumidification to

heat if Humidity setpoint

lower the fan speed.

is above room humidity.

The DHM terminal is

Can also be used to

only used on systems

provide humidification

with a compatible

independent of a call for

dehumidification feature

heat and/or in cooling

that have the required

mode if Automatic

terminal connection on

Humidification is

the contol module or

selected in Configura-

have a relay installed to

tion Menu item #34

lower the fan speed

 

 

+

S

-

 

 

 

Supply voltage

Remote

Supply voltage

to remote

temperature

to remote

temperature

sensor signal

temperature

sensor

 

sensor

 

 

 

Dehumidification wiring without an electronically controlled variable speed blower system for single stage compressor system only.

If you have a single stage compressor system see the dia- gram below. A relay (customer provided) should be installed as shown in Fig 7 to switch the fan speed to the next lower speed on a call for dehumidification from the thermostat. The reduction in air flow allows the coil to remove more humidity from the air. The relay should be rated for blower motor load. Since this configuration reduces the air flow in cooling, the

anti-freeze-up control (White-Rodgers CAFC) or equivalent is recommended. The CAFC prevents the air conditioning coil from freezing due to low air flow, dirty filters, low refrigerant pressure, etc. The CAFC snaps onto the suction line close to the evaporator coil as possible and breaks the compressor circuit when the suction line drops below 38°F and re-make the circuit at 46°F.

Figure 5 – Typical Wiring for Dehumidifier System

 

 

Normal High

DHM

 

 

 

No

Med

Relay

 

 

1

90-293Q

2

Low

or equivalent

NC

Dehum

 

 

 

Speed Fan

N

 

“Heat Fan Output”

“Cool Fan Output”

 

1Normal Cool speed position (DHM energized)

2 Dehum speed mode (DHM de-energized)

N

Figure 6 – Typical Wiring for 120V Humidifier System

HM

 

 

R

 

Relay

 

 

HOT

 

90-290Q

 

 

 

or equivalent

24 VAC

 

120 VAC

 

 

NEUTRAL

Humidifier

HOT

 

TRANSFORMER

 

NEUTRAL

120 VAC

 

System

 

 

 

 

 

 

Figure 7 – Typical Wiring for 24V Humidifier System

 

 

HM

Humidifier

System

 

R

 

24 VAC

 

 

 

 

 

 

 

 

HOT

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

4

 

 

 

 

 

 

 

 

 

 

Page 4
Image 4
White Rodgers 1F95-1291 specifications Wiring Diagrams, 24 VAC, 120 VAC, Neutral, Transformer