operation
Basic Silent Operator components are a
LINE
YELLOW
BLACK
BLUE
HEATING
LOAD
WIRING
Line Voltage
Line Voltage Field
Low Voltage
TRANSFORMER
WHITE
RED
LINE VOLTAGE
SNAP SWITCH (NORMALLY OPEN)
AMBIENT
COMPENSATING
BIMETAL
BIMETAL HEATER
Fig. 1. Internal wiring of Type 24A07
INSTALLATION
The proper location and method of installation for the Silent Operator relay shall be determined by the manufacturer of the heating equipment.A dimensional drawing of the Silent Operator relay is shown at the right.
4 1/16"
3 7/16"
2 13/32"
2 11/16"
7/16"
15/16"
9/16"
3 11/32"
1 3/8"
15/32"
9/16"
1 15/32"
Fig. 2. Dimensions of Type 24A07 Level Temp
wiring
All wiring should be done in accordance with local and national electrical codes and ordinances.
If a wiring diagram is supplied with the heating equipment, follow those instructions. If none is available, several diagrams are presented on this sheet which show different wiring meth- ods for these Silent Operator relays. Always be sure that the supply voltage agrees with the voltage rating of the Silent Operator relay.
|
|
| MAKE L2 “HOT” |
| |||||
|
|
| ON 120V MODELS |
| |||||
LOW |
|
|
|
|
|
|
|
| L1 |
VOLTAGE | LOAD |
|
|
|
|
| LINE | ||
| YELLOW |
| |||||||
THERMOSTAT |
|
| |||||||
|
|
|
|
|
|
|
| L2 | |
|
|
| BLUE |
|
| BLACK | |||
|
|
|
|
|
|
|
|
|
|
RED
WHITE
Fig. 3. Diagram of “LEVEL TEMP” Wiring