3

T1

T2

2

Z1

 

1

 

 

Fig. 4

TO TERMINALS ON

W-R 1311 OR 1361

ZONE VALVES

ZONING FOR WATER VALVES

Connect Z to 1, T1 to 2, and T2 to 3 on water zone valves as shown. Refer to sheet packed with water valves for complete wiring information. For water valves other than White-Rodgers, consult the valve manufacturer for wiring details.

ZONING WITH CIRCULATORS

All wiring should be done in accordance with local and national electrical codes and ordinances.

This diagram shows connections for either a line voltage or 24V Manifold Gas Valve. This diagram may also be used on Type 668 Kwik-Sensor Oil Burner Controls by wiring to B1 and B2 terminals as shown on preceding page.

NOTE

This diagram is not recommended for normal stack- mounted oil burner controls because rapid cycling of the low limit-circulator control may cause the oil burner control to lock out on safety.

 

 

ZONE 1

ZONE 2

 

 

ZONE 3

 

 

 

THERMOSTAT

 

 

 

 

 

THERMOSTAT

 

THERMOSTAT

 

 

 

 

 

 

 

WIRING

 

TYPE 8B43A

 

 

 

 

 

 

 

 

 

RELAY - HOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE 829A

 

 

Line Voltage

WATER CONTROL

TYPE 829A

 

 

 

 

 

Low Voltage

 

 

RELAY

 

 

 

RELAY

 

 

 

 

 

 

FIELD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

T2

 

 

INSTALLED

 

 

 

 

 

 

 

 

T

T

JUMPERS

 

T

T

 

Fig. 5

 

Z1

5

3

1

 

5

3

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

6

4

2

 

6

4

2

 

 

 

 

 

 

 

 

 

 

 

C1

C2

ZR

 

 

 

 

 

 

 

 

B1

B2

ZC

 

 

ZONE 2

 

 

ZONE 3

 

24V GAS

 

CIRCULATOR

 

 

CIRCULATOR

 

 

 

 

 

 

 

HOT

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

TRANSF.

 

 

 

 

 

 

 

 

 

 

 

ZONE 1

 

 

 

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT ADDITIONAL ZONES

 

 

 

 

 

 

 

 

 

AS SHOWN BY DASHED LINES

 

SERVICING

The temperature control of Type 8B43A controls cannot be recalibrated in the field, but it can be easily replaced by removal of two screws. Specify Part No. 77-4387 when ordering replacement.

TERMINAL DESIGNATIONS CROSS REFERENCE

Well No.

Description

A

 

B

C

W-R 829A-845

W-R 829A-1

MH R845

 

89-0211

1/2" Std. Shank

1-13/16"

 

3"

3-5/16"

 

 

 

 

 

 

 

 

 

 

 

 

 

89-0212

1/2" Std. Ext. Shank

3-5/16"

 

3"

3-5/16"

1

L

1

 

 

 

89-0213

3/4" Std. Shank

1-13/16"

 

3"

3-5/16"

2

L

2

 

 

 

89-0214

3/4" Std. Ext. Shank

3-5/16"

 

3"

3-5/16"

3

1

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

89-0215

3/4" Extra Ext. Shank

4-13/16"

 

3"

3-5/16"

4

2

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

4

6

 

Fig. 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A B

3

Page 3
Image 3
White Rodgers 8B43A-601 Zoning for Water Valves, Zoning with Circulators, Servicing, Terminal Designations Cross Reference

8B43A-601, 37-5488A specifications

The White Rodgers 37-5488A, also known as the 8B43A-601, is a versatile and advanced thermostat designed for efficient climate control in residential and light commercial environments. With its user-friendly interface and cutting-edge technology, this model has become a popular choice for homeowners and HVAC professionals alike.

One of the main features of the 37-5488A thermostat is its compatibility with a variety of heating and cooling systems, including conventional and heat pump systems. This flexibility allows it to be used in diverse settings, accommodating different HVAC configurations. Additionally, the thermostat supports both single and multi-stage heating and cooling, making it suitable for a wide range of applications.

The device is equipped with a digital display that provides clear temperature readings and system status indicators, allowing users to easily monitor and adjust settings as needed. It features an intuitive programming system that enables users to set and modify schedules effortlessly. This functionality helps optimize energy usage and maintain comfortable living conditions at all times, reducing unnecessary energy consumption.

Another significant aspect of the White Rodgers 37-5488A is its advanced algorithms that enhance system efficiency. This thermostat incorporates temperature averaging technology, which ensures accurate readings by factoring in multiple temperature sensors. This results in more precise control of the indoor climate, contributing to increased comfort and energy savings.

Energy efficiency is a key characteristic of the 37-5488A model. It includes various settings that enable users to take advantage of energy-saving modes and programmable options. With the implementation of setback temperatures during non-occupancy hours, homeowners can achieve greater energy efficiency without sacrificing comfort.

Moreover, the device features a user-friendly installation process, with straightforward wiring instructions that make it accessible even for those with limited HVAC experience. The compatibility with common wiring configurations simplifies the replacement of outdated thermostats.

In summary, the White Rodgers 37-5488A, 8B43A-601 model stands out due to its adaptable compatibility, user-friendly interface, advanced temperature sensing technology, energy efficiency features, and easy installation. These attributes combine to make it a reliable and effective thermostat choice, contributing to enhanced comfort and reduced energy costs for users.