!WARNING
FIRE HAZARD
•Do not exceed the specified voltage.
•Replace existing control with exact model and dash number.
•Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
•If the control has been in direct contact with water, replace the control.
•Label all wires before disconnection when serv- icing controls. Wiring errors can cause improper and dangerous operation.
•Route and secure wiring away from flame.
SHOCK HAZARD
•Disconnect electric power before servicing.
•Ensure proper earth grounding of appliance.
•Ensure proper connection of line neutral and line hot wires.
EXPLOSION HAZARD
•Shut off main gas to appliance until installation is complete.
!CAUTION
Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat.
INSTALLATION
MOUNTING AND WIRING
All wiring should be installed by a qualified heating and air conditioning contractor or licensed electrician, according to local and national electrical codes and ordinances.
The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 176°F. The control is approved for minimum ambient temperatures of
When mounting the control, any orientation is acceptable.
Refer to the wiring diagram and wiring table when connecting the
UL approved, 105°C rated 18 gauge, stranded, 2/64” thick insulation wire is recommended for all low voltage safety circuit connections.
UL approved 105°C rated 16 gauge min., stranded, 4/64” thick insulation wire is recommended for all line voltage connections.
Afterinstallationorreplacement,followappliancemanufacturer’s recommended installation or service instructions to ensure proper operation.
3