ELECTRIC ELEMENT

The switch located on the fan limit control activates the blower at high speed, in either automatic or manual (continuous operation) modes.

The switch located on the electric unit controls low speed operation, in either ON (continuous operation) or OFF modes (PSG 3000 or PSG 4000 models only).

WARNING: USE FEEDING WIRES SUITABLE FOR 75OC

*(With all reserves on the minimum combustion air to be increased depending on the type and quality of the combustible).

ELECTRIC ELEMENT

The WOOD / ELECTRIC combined model is installed with two thermostats: one thermostat controls the electric heating, the other one controls the wood heating. With this system, the electric heating has priority over the wood heating. When the thermostat activates the electric heating, the air inlet closes down (if opened), the blower starts and the electric elements are successively activated per block of 5 kW. The system might be equipped with an exterior thermostat which will allow the last block of elements (5 kW) to start up only when the outside temperature is cold enough. This will reduce the power of the systems by 5 kW during mild temperature for more comfort.

When the call for electric heating is completed, the wood system will take over if the starting point of the wood system is superior to the electric system.

So, in normal bi-energy use, you must set the wood system thermostat 2o to 3o higher than the electric system thermostat.

Take note that this furnace is equipped with a four speed motor. Aside from low speed, three choices are available: medium-low, medium-high or high.

If the temperature of the element exceeds the limit allowed, the thermodisk will disengage the element. For reactivation, press the red button “manual reset” of the thermodisk L-170 and find out why the temperature limit has been exceeded (static pressure too high, fan breakage, dirty filter, etc.)

INSIDE VIEW OF THE ELECTRIC ELEMENT

Red button manual reset

Thermodisk L-170

10