Part 5 Troubleshooting Guide

Part 5 Troubleshooting Guide

Problem

Possible Cause

Action

 

 

 

Snowflake

5-minute lockout

No action needed: should

icon blinking

enabled to protect

stop blinking after

 

compressor

5 minutes

No Heat, No Cool,

Blown fuse /

Replace fuse or reset

or No Fan

tripped circuit

breaker

 

breaker

 

 

Furnace power

Turn switch to ON

 

switch to OFF

 

 

Furnace blower

Replace door panel

 

compartment door

in proper position to

 

or panel loose or

engage safety interlock

 

not properly

or door switch

 

installed

 

 

Loose connection

Tighten connections

 

to thermostat

 

 

or system

 

 

Low Batteries

Replace batteries

 

 

 

Thermostat &

 

The thermometer can be

Indoor

 

adjusted +/- 4 degrees.

Thermometer

 

See Temperature Display

Setting Disagree

 

Adjustment in the

 

 

Configuration Menu section

5 Troubleshooting Guide (continued)

Problem

Possible Cause

Action

 

 

 

No Display or

Low Batteries

Replace batteries

no backlight

 

 

Thermostat

AM or PM set

Check the current

doesn’t follow the

incorrectly in the

settings including AM and

scheduled program

program

PM designations for

 

 

each time period

 

AM or PM set

 

 

 

incorrectly on the

 

 

thermostat’s clock

 

Heating or Cooling

Energy

No action required

starts earlier than

Management

 

programmed

Recovery function

 

 

activated. See

 

 

Table 3.3, Step 4

 

 

for details

 

 

 

 

Reset Operation

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by pressing all three buttons (TIME, and both Problem buttons) simultaneously. This reset will restore your thermostat’s initial factory setting.

Action5 Troubleshooting Guide (continued)Reset OperationManual background Remember to turn off your heating / cooling system BEFORE resetting your thermostat. You will then have to go through a full initial setup described in Part 3 and Part 4 of the manual before you can turn your Heating & Cooling system back on. Failure to follow this instruction may lead to your Heating & Cooling system damage or malfunction.