INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Location

The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.

Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.

Exhaust hose Installation

When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in DRY or FAN only mode, no exhaust is required.

1.Pull out about 6” of one end of the exhaust hose.

2.Install the flat mouth exhaust connector on the exhaust hose. See Fig. 18a and 18b

3.Push in the exhaust hose into the air outlet port at the back of the unit. Fig. 19 and Fig. 20.

4.Only extend the exhaust hose to the necessary length. We do not recommend extending the exhaust hose more than 9' long. If you are interested in purchasing an additional 5‟ exhaust hose please contact info@whynter.com for retail sales information.

Wall Installation

1.Prepare an adequate sized hold in the wall.

2.Install the wall exhaust adaptor A into the wall opening and hold it into place using the 4 expansion plugs and wooden screws. (See Fig.21)

3.Attach the exhaust hose to wall exhaust adaptor A.

NOTE: When the air conditioner is not in use, cover the wall exhaust adaptor with the cap.

IMPORTANT:

Do not bend or crush the exhaust hose while in use. (Fig.22)