Dust Collection System (Optional)

Installation

Transport the shipping container to the installation site. Unpack the dust collection system and check for damage. Contact the carrier if damage is found. Open the installation kit (refer to Optional Accessories in the parts listing for installation kits). Install the cover and debris collection drawer if removed. Slip a hose clamp over the 3-inch vacuum hose. Slip the hose on the inlet duct. Move the clamp over the duct to secure the hose.

Repeat the procedure to connect the hose to the outlet duct on the grinding machine.

Filter

Check for accumulation of debris. Replace the filter at intervals that you determine are appropriate for your shop environment and machine utilization.

Drawer Seal

Check the drawer seal periodically and replace if damaged or missing. Keep the seal in good condition to help maintain collection system efficiency.

Electrical Connection

Refer to the Dust Collection System Wiring Diagram for wiring information. Connection to electrical power should be made by a qualified electrician. Observe local electrical codes when connecting the machine.

Operation

The dust collection system motor is started by setting the toggle switch on the motor to the ON position. Set the switch to OFF to shut down the dust collection system.

Maintenance

WARNING:

ON/OFF switch on motor at rear of dust collection system

Removable cover – remove for interior cleaning/access to impeller

Second Inlet Duct on this side

28

·MAKE SURE YOU DISCONNECT THE ELECTRI- CAL POWER TO THE DUST COLLECTION SYS- TEM BEFORE PERFORMING MAINTENANCE. FAILURE TO DO SO MAY RESULT IN INJURY TO THE OPERATOR AND/OR MAINTENANCE PERSONNEL.

·DO NOT OPERATE THE DUST COLLECTION SYSTEM WITH THE COVER REMOVED. INJURY TO FINGERS AND HANDS FROM THE FAN BLADES, AND INGESTION OF LOOSE FITTING CLOTHING INTO THE AIR INLET WITH RESULTANT INJURY IS ALSO POSSIBLE.

Cleaning

Outlet filter at rear removes fine debris from outlet air stream

Inlet Duct – Connect 3 inch hose - secure with clamp

Chip Drawer - Pull to Open

Periodically dispose of accumulated chips and debris from the chip drawer. Use a brush to loosen debris from internal surfaces. Use a vacuum cleaner to clean up the loosened debris.