CARPET INSPECTION:

Determine precisely what areas you are going to clean. Note problem areas in the carpet or tack strip. Look for loose carpet, heavily damaged areas, discolored stains, or grease spots that will require prespotting. Note the carpet type. Check the availability of hot water, drains, and suitable electrical outlets. If the carpet is loose or worn, have it repaired before attempting to clean it.

Plan the cleaning route, work from the most remote area towards the exit. Try not to travel over the cleaned areas when getting fresh water or dumping old. Furniture should be moved out away from the walls before cleaning. If furniture is moved back in place before carpet is completely dry, place plastic or foil protectors under the legs to prevent possible carpet staining. When possible use a Windblower (AM3) and open all windows and doors to speed carpet drying.

ACCESSORIES:

The D100 can be used with the following Windsor equipment: Deluxe Hand Tool (86000020 – PRV NO. HT), Pile Jogger (86041760 – PRVNO. PJ2A), Standard Floor Wands(SFW, 86000610 – PRV NO. 89227, 86000600 PRV NO. 89226, & Wind Blower carpet dryer(AM3). Contact an authorized Windsor dealer for assistance in choosing the right equipment .

GENERAL INFORMATION:

On heavily soiled carpets, or on areas of high foot traffic, it may be necessary to use a prespray or traffic lane cleaner applied with a Pro-Spray. Do not add presprays to the machine's solution tank. If a spotter is used, follow the manufacturer's instructions exactly as printed on the label. Remove the spotter with the floor tool when done, spotter left in the carpet may bleach or brown it permanently.

As the carpet is being cleaned, check to see if there is foam building up in the recovery bucket. Add a little defoaming compound to the recovery tank but never to the solution tank.

OPERATIONS

For infrequent use or long periods of storage, flush the system with a neutralizing solution of 1 quart white vinegar mixed with 2 gallons hot water. Flush the system with clean hot water after neutralizing.

For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.

PROTECT THIS MACHINE FROM FREEZING.

EQUIPMENT SET-UP:

1.) Plug power cable from machine into properly grounded wall outlet.

2.) Turn vacuum motor switch on and off to make sure there is electrical power at machine.

3.) Connect vac hose to machine. Slide the swivel cuff over the outlet on the tank.

4.) Connect the hose set to your machine and wand. Pull back the knurled collar on the quick disconnect coupler and push onto the connection on the chassis. To avoid leaks, check to be sure a positive connection was made.

5.) Using a clean container, fill the solution tank with clean, hot water. Mix in a non- foaming cleaning concentrate for use in hot water extraction machines following the manufacturer's instructions, as printed on the container. When using a powder cleaner, premix with hot water in a clean container before adding to the solution tank.

6.) Turn pump and vacuum switch to the on position.

7.) Start cleaning.

D100 86038620 05/21/07

3-2

Page 9
Image 9
Windsor 10070090, D100 manual Operations

D100, 10070090 specifications

The Windsor D100, model number 10070090, is a cutting-edge cleaning machine designed for efficiency and effectiveness in maintaining various floor types. As part of Windsor’s iconic line of cleaning solutions, the D100 stands out due to its innovative features, advanced technologies, and exceptional design characteristics that cater to the needs of professional cleaning teams and facility managers.

One of the main features of the Windsor D100 is its powerful motor, which delivers high suction capabilities, ensuring thorough dirt and debris removal from carpets, hard floors, and other surfaces. The machine operates quietly, making it suitable for use in noise-sensitive environments such as hotels, offices, and healthcare facilities. With a lightweight design, the D100 is easy to maneuver around furniture and obstacles, enhancing the overall cleaning experience.

The D100 also incorporates a robust filtration system, complete with HEPA filters, which captures even the smallest allergens and particles. This is crucial for maintaining air quality, particularly in spaces where individuals may have allergies or respiratory issues. The smart engineering of the filtration system ensures that maintenance is straightforward, with easy access to filter replacement, allowing for consistent performance over time.

In terms of technology, the Windsor D100 employs advanced electronic controls that enable users to customize settings based on cleaning requirements. The machine is equipped with intelligent sensors that automatically adjust suction power when transitioning between different floor types, optimizing cleaning efficiency while conserving energy. This user-friendly interface is designed to simplify operation and enhance productivity.

Another notable characteristic of the Windsor D100 is its durable construction. Built with high-quality materials, the machine is engineered to withstand the rigors of daily use in demanding commercial environments. The sturdy design not only increases the lifespan of the unit but also minimizes maintenance costs over time.

In summary, the Windsor D100 (10070090) combines powerful cleaning performance with advanced technology and user-friendly features. It addresses the diverse needs of professional cleaning tasks while providing excellent filtration and longevity. As a result, it remains a popular choice among commercial cleaning services and businesses looking to maintain clean and hygienic spaces.