MACHINE TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
Machine will not run | Tripped circuit breaker | Reset |
|
|
|
| Circuit breaker tripped in | Check and reset |
| building. |
|
| Fuse in motor is blown | Replace |
|
| CAUTION: To reduce the risk |
|
| of electrical shock, unplug the |
|
| machine before opening fuse |
|
| holder. |
|
| Fuse will only open under |
|
| extreme conditions. |
|
| Investigate cause before |
|
| replacing. |
| Power switch failure | Test switch for continuity and |
|
| replace if necessary. |
| Faulty power cord | Replace |
|
|
|
| Equipment not grounded | Follow grounding instructions |
|
| exactly. |
| Receptacle not grounded | Have an electrician inspect |
Electrical shock |
| building’s wiring. |
Internal wiring problem | Ensure that the machine | |
|
| wiring matches the |
|
| appropriate wiring diagram. |
|
| Replace any wires or |
|
| components which are short |
|
| circuiting. |
| Mechanical problem | Higher amp draws indicate a |
|
| mechanical problem, find the |
Repeated circuit breaker tripping |
| problem before using the |
| machine. | |
| Faulty circuit breaker | Test circuit for continuity. |
|
| Replace circuit breaker if |
|
| necessary. |
| Pad not centered | |
|
|
|
Excessive vibration | Damaged or unevenly worn | Replace pad. Do not rest |
pad. | machine on pad when not in | |
|
| use. |
| Damaged pad driver. | Replace. |
|
|
|