MACHINE TROUBLESHOOTING

MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Machine will not run

Tripped circuit breaker

Reset

 

 

 

 

Circuit breaker tripped in

Check and reset

 

building.

 

 

Fuse in motor is blown

Replace

 

 

CAUTION: To reduce the risk

 

 

of electrical shock, unplug the

 

 

machine before opening fuse

 

 

holder.

 

 

Fuse will only open under

 

 

extreme conditions.

 

 

Investigate cause before

 

 

replacing.

 

Power switch failure

Test switch for continuity and

 

 

replace if necessary.

 

Faulty power cord

Replace

 

 

 

 

Equipment not grounded

Follow grounding instructions

 

 

exactly.

 

Receptacle not grounded

Have an electrician inspect

Electrical shock

 

building’s wiring.

Internal wiring problem

Ensure that the machine

 

 

wiring matches the

 

 

appropriate wiring diagram.

 

 

Replace any wires or

 

 

components which are short

 

 

circuiting.

 

Mechanical problem

Higher amp draws indicate a

 

 

mechanical problem, find the

Repeated circuit breaker tripping

 

problem before using the

 

machine.

 

Faulty circuit breaker

Test circuit for continuity.

 

 

Replace circuit breaker if

 

 

necessary.

 

Pad not centered

Re-center pad.

 

 

 

Excessive vibration

Damaged or unevenly worn

Replace pad. Do not rest

pad.

machine on pad when not in

 

 

use.

 

Damaged pad driver.

Replace.

 

 

 