Preparing the SPIRIT DUAL:

For Hard Floor:

1.) Install the optional kit : Vac Shoe Squeegee (p/n 02285). Raise the SPD vac shoe and place the squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and secure by tightening the two retain- ing knobs.

CAUTION: Make sure that the machine is un- plugged, switches are turned off and both solution tanks are empty before beginning brush removal or replacement.

2.) Now install the hard floor brush. Tilt the machine back far enough to grasp the brush. If the carpet brush is already installed, proceed with step 3 to remove it. If no brush is installed, proceed with step 4.

3.) To remove brush, pull the brush release knob back until the brush can be swung out from the housing and pull the brush off of the drive end.

4.) To replace, align the pulley drive pins on the knob driver in the housing with the slots in the brush and slide over the knob driver.

5.) Pull the brush release knob back, align the flat sides of the brush stub axle in the housing and swing the brush into place. Then release the knob, returning to the locked position. Refer to page 17 for parts

outlined in these steps.

6.) Set the water control switch on the front of the machine to “LOW”. NOTE: If water does not spray after 5 seconds when the switch is in the “LOW” position it may be necessary to place it in the “HIGH” position to start the flow, then return it to the “LOW” position for hard floor use.

For Carpet:

1.) Remove squeegee from vac shoe by loosening the two retaining knobs.

2.) Install carpet brush as described above.

3.) Set the water control switch on the front of the machine to “HIGH”.

Filling Solution Tank:

1.) Set dome and recovery tank to the side.

2.) Use a clean bucket to fill the solution tank with hot water.

3.) If necessary add a cleaning concentrate for use in hot water extractors. Closely follow manu- facturer’s instructions found on container. Read ingredients listed on the container to ensure com-

CAUTION: Use only the suitable chemicals listed below. Using incompatible chemicals will damage the machine. Damages of this type are not covered under warranty. Carefully read ingredients on manufacturer’s label before us- ing any product in this machine.

SUITABLEINCOMPATIBLE

CHEMICALSCHEMICALS

Alkalis

Aldehydes

 

Clorox II Bleach*

Aromatic

Hydrocarbons

Defoaming Agents

Butyls

 

 

Detergents

Carbon

Tetrachloride

Hydroxides

Clorox*

 

 

Oxygen Bleaches

Chlorinated

Bleaches

Soaps

Chlorinated

Hydrocarbons

Sta-Puf Fabric Softener*

D-Limonene

Vinegar

Lysol*

 

 

White Monday Bleach*

Methyls (MEK)

 

Perchlorethylene(perc)

 

Phenols

 

 

Registered Trademark

Trichlorethylene

 

 

 

 

4.) Place the recovery tank onto the solution tank.

5.) Set the dome in place on the recovery tank. Dome must be seated correctly to ensure proper vacuum seal.

98353

5

Page 5
Image 5
Windsor SPD-J manual Filling Solution Tank, Preparing the Spirit Dual For Hard Floor

SPD-J, SPD specifications

Windsor SPD and SPD-J are advanced power distribution systems designed with a focus on efficiency, reliability, and innovation. Windsor SPD, also known as Surge Protective Device, is engineered to protect electrical systems from voltage spikes that can result from lightning strikes, power surges, or other disturbances. This device is crucial for safeguarding sensitive electronic equipment used in various industries, from telecommunications to healthcare.

One of the main features of the Windsor SPD is its multi-level protection mechanism. It employs a tiered approach that combines several surge protection technologies, including metal oxide varistors (MOVs), gas discharge tubes (GDTs), and transient voltage suppressors (TVS). This combination not only enhances performance but also extends the lifespan of the protective equipment, effectively minimizing the risk of failure during transient events.

The SPD-J model introduces added functionalities and improved integration capabilities. It includes an intuitive monitoring interface that provides real-time insights into system performance and surge events. This data is crucial for facility managers as it enables them to assess the effectiveness of surge protection and make informed decisions about maintenance and upgrades.

Both the Windsor SPD and SPD-J feature compact designs that allow for easy installation in various settings, including residential, commercial, and industrial environments. Their robust construction ensures compliance with international safety standards, providing users with peace of mind regarding their efficacy.

In terms of technology, these devices are equipped with remote monitoring capabilities. Users can access performance data via web applications, enabling proactive management of electrical systems. Additionally, they are designed to integrate seamlessly with existing electrical infrastructure, making them a versatile solution for enhancing overall system resilience.

Regarding characteristics, the devices boast high energy absorption ratings, which define their ability to withstand and dissipate surges without compromising performance. The SPD and SPD-J are also designed to operate in a wide range of temperatures, ensuring reliability in diverse climate conditions.

In summary, Windsor SPD and SPD-J stand out in the field of surge protection technologies for their effective, user-friendly, and reliable solutions. As power demands continue to grow, these systems play an essential role in maintaining the integrity and safety of electrical systems across various sectors.