Preparing the SPIRIT DUAL:

Preparing the SPIRIT DUAL:

For Hard Floor:

1.) Install the optional kit : Vac Shoe Squeegee (p/n 02285). Raise the SPD vac shoe and place the squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and secure by tightening the two retain- ing knobs.

CAUTION: Make sure that the machine is un- plugged, switches are turned off and both solution tanks are empty before beginning brush removal or replacement.

2.) Now install the hard floor brush. Tilt the machine back far enough to grasp the brush. If the carpet brush is already installed, proceed with step 3 to remove it. If no brush is installed, proceed with step 4.

3.) To remove brush, pull the brush release knob back until the brush can be swung out from the housing and pull the brush off of the drive end.

4.) To replace, align the pulley drive pins on the knob driver in the housing with the slots in the brush and slide over the knob driver.

5.) Pull the brush release knob back, align the flat sides of the brush stub axle in the housing and swing the brush into place. Then release the knob, returning to the locked position. Refer to page 17 for parts

outlined in these steps.

6.) Set the water control switch on the front of the machine to “LOW”. NOTE: If water does not spray after 5 seconds when the switch is in the “LOW” position it may be necessary to place it in the “HIGH” position to start the flow, then return it to the “LOW” position for hard floor use.

For Carpet:

1.) Remove squeegee from vac shoe by loosening the two retaining knobs.

2.) Install carpet brush as described above.

3.) Set the water control switch on the front of the machine to “HIGH”.

Filling Solution Tank:

1.) Set dome and recovery tank to the side.

2.) Use a clean bucket to fill the solution tank with hot water.

3.) If necessary add a cleaning concentrate for use in hot water extractors. Closely follow manu- facturer’s instructions found on container. Read ingredients listed on the container to ensure com-

CAUTION: Use only the suitable chemicals listed below. Using incompatible chemicals will damage the machine. Damages of this type are not covered under warranty. Carefully read ingredients on manufacturer’s label before us- ing any product in this machine.

SUITABLEINCOMPATIBLE

CHEMICALSCHEMICALS

Alkalis

Aldehydes

 

Clorox II Bleach*

Aromatic

Hydrocarbons

Defoaming Agents

Butyls

 

 

Detergents

Carbon

Tetrachloride

Hydroxides

Clorox*

 

 

Oxygen Bleaches

Chlorinated

Bleaches

Soaps

Chlorinated

Hydrocarbons

Sta-Puf Fabric Softener*

D-Limonene

Vinegar

Lysol*

 

 

White Monday Bleach*

Methyls (MEK)

 

Perchlorethylene(perc)

 

Phenols

 

 

Registered Trademark

Trichlorethylene

 

 

 

 

4.) Place the recovery tank onto the solution tank.

5.) Set the dome in place on the recovery tank. Dome must be seated correctly to ensure proper vacuum seal.