Troubleshooting Chart

 

Troubleshooting Chart

Condition

Corrective Action

Accessory Tool Fitting Difficult to Connect:

Corrosion on fitting

Clean with steel wool.

Remove and soak in acetic acid (white vinegar).

Lubricate lightly with silicone base lubricant.

Floor Not Getting Clean:

Severe soil conditions

Floor Too Wet:

Worn spray jet(s)

Floor Not Getting Wet:

Solution filter screen clogged

Spray jet(s) clogged

Pump not running

Faulty pump

Solution valve adjustment

Brush Not Turning:

Belt broken

Faulty switch

Faulty circuit breaker

Faulty brush motor

Worn Bearings:

Squeeling or grinding sound in brush housing

Make several passes at right angles to each other.

Use a prespray.

Replace spray jets which are producing more than a fine mist.

Clean solution filter screen located inside lower tank near the front.

Clean or replace jets.

Do not use a wire to clean jet.

Damaged jets will cause over-saturation.

Check for and correct any loose wires

Repair or replace

Adjust solution valve cable until valve operates when handle is pulled.

Remove belt cover on right side of machine. Inspect belt. Replace if necessary.

Replace.

Replace.

If the belt, circuit breaker, and switch have been tested and found to be in good working order, the brush motor may need to be replaced.

Replace bearings.