WARNING OF POTENTIAL INJURY
This product contains moving parts.
To reduce the risk of injury; unplug the machine before servicing.
Maintenance and repairs must be done by qualified personnel ONLY.
CAUTION:
Using
Suggested Service Parts List
|
| DESCRIPTION | PART NUMBER | ||
| Belt |
|
| 11031 |
|
| Brush Bearing | 09019 |
| ||
| 115V Cord Assembly (USA/Japan) 23572 | ||||
| 230V Cord Assembly (Europe) | 23178 |
| ||
| Dome | Assembly | 28034 |
| |
| Dome | Gasket | 35060 |
| |
| Hose Cuff. Short Blue | 27508 |
| ||
| Hose Cuff. Longer Blue | 27354 |
| ||
| Hose Cuff, White | 27079 |
| ||
Jet Assembly |
| 44055 |
| ||
Jet |
|
| 44061 |
| |
Jet Seal |
| 44051 |
| ||
Jet Body w/Seal | 44052 |
| |||
Manifold Assembly (No Jets) | 54094 |
| |||
Pump Service Kit | 47176 |
| |||
Screen/Filter, | Dome | 34140 |
| ||
Screen/Filter, | Solution Tank | 73250 |
| ||
Solution Release Cable | 27665 |
| |||
Solution Release Lever | 51200 |
| |||
| 115V Switch |
| 72074 |
| |
230V Switch |
| 72121 |
| ||
Valve |
|
| 84134 |
|
Dailv Maintenance:
These procedures are followed at the end of each work period to extend the life of the ma- chine.
1.) Empty unused cleaning solution by disconnecting clear hose on back of machine and pouring into floor drain.
2.) Inspect and clean solution filter screen inside tank and vac intake screen inside dome.
3.) Flush the system. Fill solution tank with 1 or 2 gallons (4 - 8 liters) of clean hot water. With machine over floor drain turn on vac/pump switch until solution tank is empty.
4.) Inspect spray pattern of jets. Remove jets and rinse if clogged.
5.) After each use, rinse recovery tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
6.) Remove any lint or debris from brush.
7.) Inspect power cord. Remember, this cord will lay on a damp surface.
Warning:
IMMEDIATELY REPLACE WORN OR
FRAYED POWER CORDS.
8.) Inspect hoses. Worn or cracked hoses may cause loss of vac pressure.
9.) Place the brush in the storage position. Press back slightly on the main handle, and place the brush adjustment lever in the “STORE”position.
For infrequent use or long periods of stor- age, flush the system with a neutralizing solution of 1 quart (1 liter) white vinegar mixed with 2 gal- lons (8 liters) hot water. Flush the system with clean hot water after neutralizing.
8